3
. Periodical check
Field Service Ver.
3
.0 Jan. 2008
1
8
FS-519/PK-510/OT
-602
Maintenance
4.
Remove the wire saddle [1] and the
screw [2]. Remove the ground termi-
nal.
5.
Remove three screws [1] and
remove the Elevator motor assy [2].
NOTE
• Remove the elevator motor assy
while holding the lower part of the
tray [3] with your hand.
NOTE
• Before reinstalling the elevator
motor assy, raise the tray [3] until
the lever [1] attached on the timing
belt moves to the position lower
than that of the sensor [2]. In that
state, reinstall the elevator motor
assy.
A01GF2C560DA
[2]
[1]
A01GF2C561DA
[3]
[1]
[2]
A01GF2C562DA
[3]
[1]
[2]
Service Manual Y10