73
SET 901 - SET SERIAL CHANNEL 1 INFORMATION
SET903 - SET SERIAL CHANNEL 2 INFORMATION
The values set automatically are the defaults. You can subsequently modify these values using
code 901 (for serial 1) and code 903 (for serial 2).
Programmable parameters
DESCRIPTION
Factory settings for
connection of a PC
Factory settings for connection of
BARCODE READER
Power supply
DISABLED
ENABLED
Modem signals
Disabled
Disabled
Baud rate
9600
9600
Data bits
8
7
Stop bits
1
1
Parity No
Even
ACK/NACK time-out
3000
0
Session time-out
0
0
Number of retries
2
0
The values set automatically are the defaults or those set by the user.
Operating procedure
1. 9
.
.
0
.
.
1
.
.
X
.
or
.
9
.
.
0
.
.
3
.
.
X
.
2.
.
0
.
.
X
.
.
1
.
.
X
.
To disable the 5V power supply to the connector output.
To enable the 5V power supply to the connector output.
3.
.
0
.
.
X
.
.
1
.
.
X
.
To disable the modem signals.
To enable the modem signals.
4.
.
0
.
.
X
.
.
1
.
.
X
.
.
2
.
.
X
.
.
3
.
.
X
.
.
4
.
.
X
.
.
5
.
.
X
.
.
6
.
.
X
.
.
7
.
.
X
.
.
8
.
.
X
.
.
9
.
.
X
.
To select the baud rate:
300
600
1200
2400
4800
9600
19200
38400
57600
115200
5.
.
0
.
.
X
.
.
1
.
.
X
.
To program the data bits as 7
To program the data bits as 8
6.
.
0
.
.
X
.
.
1
.
.
X
.
To program the number of stop bits as 1
To program the number of stop bits as 2
7.
.
0
.
.
X
.
.
1
.
.
X
.
.
2
.
.
X
.
To program “no parity”
To program “odd parity”
To program “even parity”
8.
[
Numeric Chars
]
.
X
.
To program ACK/NACK time-out (between 0 and 30,000 ms).
9.
[
Numeric Chars
]
.
X
.
To program the session time-out (between 0 and 30,000 ms).
10.
[
Numeric Chars
]
.
X
.
To program the number of retries (from 0 to 250).
Summary of Contents for NETTUNa3000
Page 1: ...PROGRAMMING USING SET CASH REGISTER NETTUN 3000int l ...
Page 6: ......
Page 104: ...Code 578204gb ...