683311W
4-48
4.6.10 SCANNER BRUSH DISTANCE ADJUSTMENT
Proceed as follows to make this adjustment:
1. Power on the printer with its cover open and while holding down the three console keys.
2. Wait for an acoustic signal to indicate that the printer has switched into the adjustment mode and
close the cover.
3. Press the "Station 1" key.
4.
Insert an A4 sheet of paper without aligning it.
5. If calibration was not successful, press the "Station 1" button to block scanner usage; the sheet is
ejected and the system returns to the main menu.
6. Repeat the procedure from step 1.
COVER OPEN
MACHINE POWERED ON
LED STATION 1 ON
CALIBR.
NOT OK?
YES
NO
INSERT AN A4 80g SHEET
WITHOUT ALIGNING IT
CALIBRATION OK
SHEET EJECTED
Press the STATION1 key to
block scanner usage
READY
LOCAL
STATION2
flashing
RETURN TO THE MENU
SHEET EJECTED
■