Page | 42
9
DAILY
It is lit when the daily programming mode is set (TIMER daily)
10
WEEKLY
It is lit when the weekly programming mode is set (TIMER weekly)
11
WEEK
It is lit when the weekend programming mode is set (TIMER wkend).
It is lit when the lamp is in operation.
12 LAMP/ON
During programming it is lit in order to indicate a heater lighting
schedule.
It is lit throughout the period of time the screw is in operation, that is
when the pellet auger motor is in operation.
13 SCREW/OFF
During programming it is lit in order to indicate a heater
extinguishing time schedule.
14
AMBIENT FAN
It is lit when the heating fan is active and the ambient thermostat is
not in use. It is flashing when the heating fan is active and the
ambient thermostat is also in use. It is not lit for heating fan disabled.
DISPLAY
In non-menu mode it displays the level of operating power.
BOTTOM LEFT
DISPLAY
In menu mode it displays the size identification code.
If the heater is OFF or on it displays the ambient temperature.
With the stove on in non-menu mode, it displays the ambient
thermostat temperature.
15
BOTTOM RIGHT
DISPLAY
In menu mode it displays a size identification code
With the stove OFF or on in NORMAL condition, the display shows
the time schedule.
With the stove on, it displays the condition of operation and any
error that has occurred.
16 TOP
DISPLAY
In menu mode, it displays the name of the menus and the
submenus, as well as the size values.
(*) By pressing at the same time and keeping pressed the buttons POWER + and POWER -,
it is possible to load the pellet inside the pan. This operation is necessary when lighting for
the first time and whenever the pellet runs out in the tank and the heater is extinguished.
To light it again, after having refilled the tank, perform this operation to fill the auger
again. When the pellet begins to fall into the pan, release the buttons and proceed to
relight the product.
(**) Procedure of changing the temperature value of the ambient thermostat:
The temperature of the ambient thermostat indicates the maximum temperature that
the user would like in the room (max 30ºC). If the ambient temperature detected by the
probe is higher than the value set, the heater goes into MODULATION condition in order
to reduce the amount of heat transferred to the outside environment.
It is possible to display the thermostat temperature by pressing once only one of the
buttons TEMPE or TEMPERATURE -. Press these buttons again to proceed to a
variation of the value displayed. In order to memorize the new setting, wait 10 seconds
until the display flashes once (at this point it has been saved).