Page | 67
Figure 4.8: Side slits.
The slit will only be visible after its cover has been removed. (figure 4.8)
Now it is possible to perform the cleaning, using the brush.
ERGOFLAM IDRO
i
The side slits are also present in the ERGOFLAM IDRO version (two on each
side) and can be reached as described above for the air version.
Every 2 years it is necessary to clean the steel fan of the fume extractor and its
housing.
This part can be reached after having removed the side ceramic panels and after
removing the four screws that hold the fan. The cleaning can be performed more
easily with a vacuum cleaner.
"
For the supply of any spares, we recommend you contact the assistance
centres for further information and advice on products to purchase.
"
When replacing the covers of the side slits (both in the IDRO version and in the
AIR version), we recommend sealing the closure in order to guarantee
airtightness, using for example non-refractory high-temperature silicone.