21
Installing the stove
The floor on which the stove is installed must be even and
horizontal. The stove may only be installed on an adequate
load-bearing floor. The stove can be stood on a metal floor
sheet or glass sheet to protect the flooring.
If the flooring or carpet is inflammable, a stable and non-
combustible spark protection plate must be used. This
must extend 50 cm to the front and 30 cm to each side
beyond the edge of the combustion chamber opening.
Under the stove no spark protection plate is required.
Assembly sequence
●
If specified, install the electric stove controller OEC.
●
The Ø 150 mm stove pipe can be connected either at the
top or at the bottom / on the side, while the Ø 125 mm
combustion air line can be connected either at the bot-
tom or at the rear / on the side.
The unit is delivered pre-assembled for stove pipe and
combustion air line connection at the top and the bot-
tom, respectively.
Connection at the rear
If it is supposed to be connected at the rear, then it must
remounted in the following steps:
- Knock the cover for the stove pipe connection and
the cover for the combustion air line connection out
of the back panel
- Swap the top connection duct and the rear sealing
cover.
- Swap the bottom combustion air duct and the rear
sealing cover.
Connection on the side
Installation on the side requires that back panel and
side panel be remounted following the steps below:
- Loosen the fastening screws (A) for the back panel
and the fastening screws (B) for the side panel on the
unit (by no more than 2 turns, see Fig.1).
- Loosen the fastening screws (C) for the back panel
and the fastening screws (D) for the side panel on the
unit (by no more than 2 turns, see Fig.2).
A B
Fig.1
Fig.2
C D