Combustion air slide valve
Operating lever for combustion air supply
●
Operating lever on
„0“:
all slide valves closed
●
Operating lever on
„I“:
Secondary air slide valve completely open /
Primary air slide valve completely closed
●
Operating lever on
„II“
:
Secondary air slide valve completely open /
Primary air slide valve completely open
Regulation of combustion air
Position of operating lever:
„II”
..... Ignition position, max. heat output
„I“
....... Nominal heat output with billet wood
„I“
....... Nominal heat output with wood briquettes
„0“
..... Obtain glow
●
As the secondary air also contributes to the cleanliness
of the glass pane, the operating lever should be set on
“I” minimum. This also applies in the event of low-load
operation.
●
When not operating the lever should be set on “0”, to re-
duce the cooling down of the room.
Fire grate
Operating lever for the fire grate
●
With the help of the operating lever the fire grate can
be opened or closed to move the ash from the combus-
tion chamber to the ash pan by pushing the fire grate
back and forth.
●
Primary air can only enter the combustion chamber if
the fire grate is set on open position.