66
Warning messages
If a warning is present, a running combustion process will be stopped. As long as the appliance is in the combustion
process the warning message will be continuously visible.
If an error message occurs in idle status, start of the combustion process will not be allowed. The warning message
is visible every 30 seconds for 5 seconds.
Display
Possible cause of error
Elimination
automatic
door open
ESC
Combustion chamber door open.
Ash box is not installed correctly.
Close combustion chamber door.
Push in ash box and lock.
automatic
ext. request
ESC
blocked
Plug (Fig.5) not plugged.
External room thermostat is not or incor-
rectly connected.
The temperature set on the external
room thermostat is lower than the ac tual
room temperature.
Plug in.
Connect external room thermostat.
Wait until the actual room temperature
has cooled and the appliance starts au-
tomatically.
Increase the desired temperature on the
room thermostat.
automatic
outside
ESC
time program
Active time programs are stored, howev-
er the actual time is outside of the current
time programs.
In addition, in “automatic” mode no night
set temperature is stored.
Wait until the actual time is within the ac-
tive time programs and the appliance
starts automatically.
Redefine time programs.
Define night set.
automatic
flame temp.
ESC
too hot
The flame temperature is too high.
Wait until the flame temperature has
cooled and the appliance starts automat-
ically.
automatic
room temp.
ESC
too hot
The actual room temperature is too high
(only for “automatic” mode).
Wait until the actual room temperature
has cooled and the appliance starts au-
tomatically.
Increase the desired room temperature.
automatic
cover open
ESC
Pellet tank cover open.
Close pellet tank cover.
automatic
too hot
water temp.
ESC
The water temperature in the stove is too
high.
Wait until the actual water temperature
has cooled and the appliance starts au-
tomatically.