background image

15

Heating

 

Only place the quantity of fuel required to achieve the 

heating requirement.
For a nominal heating output 5,0 kW:

- max. 1,5 kg billet wood; burning time >45 min

- max. 1,3 kg wood briquettes; burning time >45 min
For max. heat output allowed:

- max. 3 kg billet wood

- max. 3 kg wood briquettes

 

Open the combustion chamber door slowly for add-

ing new fuel, as otherwise the combustion gases can 

escape.

 

Empty the ash pan or combustion chamber in good 

time. Otherwise it is possible for the combustion air in-

take to be blocked or for the grate to be damaged.

 

Only remove the ash pan to empty it.

 

Clean the ash pan compartment regularly after remov-

ing the ash pan to remove any ash that may have been 

spilled (e.g. use a vacuum cleaner).

Attention: 

Stove and any ash residues must have been left to 

cool before being removed.

Heating during the transition period

Prerequisite for the stove to function well is the correct 

delivery pressure (chimney draught). This very much de-

pends on the external temperature. Therefore, if the exter-

nal temperatures are high (above 16°C) the delivery pres-

sure can be disrupted.

What to do?

 

Open the combustion air slide valve complete.

 

Only put on a small quantity of fuel.

 

Frequently stoke the ash.

Cladding

 

The cladding may not be overheated, as cracks could 

appear.

 

Use a maximum of 3 kg wood or briquette for heating.

 

As the natural cladding comes from a „grown“ boulder, 

structure and colour scheme may be very different.

 

The surface may be altered under temperature 

influence.

Special information

The manufacturer’s guarantee expires if the stove is sig-

nificantly or permanently overloaded above the nominal 

heating output, or if fuels other than those listed are used.

 

The stove must only be used with the combustion 

chamber door shut.

 

Never remove hot ashes. Only store ashes in a fireproof, 

non-combustible container.

 

Attention: 

The surfaces get hot! Always use the en-

closed glove when operating the stove.

 

Convection air openings may not be covered.

 

Never use white spirit, benzene or other inflammable, 

hazardous materials to ignite the fire.

 

The combustion air supply fittings must never be al-

tered. In particular, it must be ensured that any neces-

sary combustion air pies are open while the fireplace is 

being used.

 

Do not make any changes or modifications to the stove.

Summary of Contents for Libra

Page 1: ...Kaminofen Libra 28 915 DIN EN 13240 15a BV G EN D F Anleitung Seite 2 9 Instruction Page 10 16 Instructions Page 17 23...

Page 2: ...r die richtige Bedienung informieren k nnen Transportsch den sind umgehend innerhalb von 2Ta gen an Ihren Lieferanten zu melden Technische Daten Nennw rmeleistung 5 0 kW Raumw rmeleistung 5 4 kW Ansch...

Page 3: ...dichte Leitung oder ber ein LAS System zugef hrt werden Sprechen Sie deshalb mit Ihrem Bezirksschornsteinfegermeister Aus Energiespargr nden EnEV sollte bei Nichtbetrieb des Kaminofens die Verbrennun...

Page 4: ...inofen vor zu sch tzen den W nden brennbar oder tragend montiert wird sind entsprechend der Position der Feuerraumt r zur Aufstell bzw Seiten oder R ckwand folgende Wandabst nde einzuhalten siehe Prin...

Page 5: ...pier und Pappe au er zum Anz nden Stroh Beachten Sie vor dem ersten Heizen Alle Zubeh rteile aus dem Aschekasten und Feuerraum entnehmen Der auftretende Geruch durch das Verdampfen der Schutzlackierun...

Page 6: ...Abbrand mindestens auf I zu stellen Dies gilt auch bei Schwachlastbetrieb Bei Nichtbetrieb den Bedienhebel auf 0 stellen um ein Ausk hlen des Aufstellraumes zu verhindern Feuerrost Bedienhebel f r de...

Page 7: ...mmen Was tun Verbrennungsluftschieber ganz ffnen Nur kleine Menge Brennstoff auflegen Asche h ufig sch ren Verkleidung Die Verkleidungen d rfen nicht berheizt werden da sonst Risse auftreten k nnen Mi...

Page 8: ...einzutragen Typnummer 28 __________ Fabrikationsnummer _________________________ Was ist wenn der Kaminofen nicht richtig zieht Ist der Schornstein oder das Ofenrohr undicht Ist der Schornstein nicht...

Page 9: ...tellt Farbun terschiede bei Glasuren sowohl in Helligkeit als auch Farbt nung k nnen von Keramikbrand zu Keramik brand in Nuancen auftreten Diese Unterschiede k nnen deutlich bei Lieferung von einzeln...

Page 10: ...ty space heating without having to do without the cosy atmosphere of an open fire Proper installation and correct handling and care are in dispensable for problem free operation and a long ser vice li...

Page 11: ...gh a supply duct in the chimney Thus speak with your district chimney sweep master Due to energy saving reasons the combustion air inlet should be able to be blocked if the stove is not being op erate...

Page 12: ...that need to be protected flammable or load bearing the following distances from walls need to be observed in accordance with the position of the combustion chamber door to the wall side panel or the...

Page 13: ...ollowing fuels in stoves Moist wood or wood treated with wood preservatives Sawdust chippings grinding dust Bark and chipboard waste Slack coal Other wastes Paper and cardboard except for igniting Str...

Page 14: ...e secondary air also contributes to the cleanliness of the glass pane the operating lever should be set on I minimum This also applies in the event of low load operation When not operating the lever s...

Page 15: ...gh above 16 C the delivery pres sure can be disrupted What to do Open the combustion air slide valve complete Only put on a small quantity of fuel Frequently stoke the ash Cladding The cladding may no...

Page 16: ...hand Type number 28 __________ Fabrication number __________________________ What to do if the stove doesn t draw properly Is the chimney or the stovepipe not tight Has the chimney been incorrectly de...

Page 17: ...e int rieur de qualit sans devoir renon cer l atmosph re douillet d un feu de chemin e L installation en bonne et due forme ainsi que le manie ment et l entretien correct du po le sont indispensables...

Page 18: ...tion est plus long que 3 m il faut fournir le calcul jus tificatif pour l alimentation en air de combustion Dans le cas de tr s basses temp ratures ext rieures de la conden sation peut se former sur l...

Page 19: ...a porte du foyer de respecter les carts suivants avec le mur d installation le panneau la t ral ou arri re voir sch ma de principe Si le po le n est pas mont proximit de murs pro t ger il convient de...

Page 20: ...mbustibles suivants dans les po les chemin e Bois humide resp trait avec des produits de pr servation du bois Sciure de bois copeaux poussi re de meulage D chets d corce et d agglom r s Menus de houil...

Page 21: ...res il faut toujours placer le levier de commande au minimum sur I durant la combustion Ceci est aussi valable en cas d exploitation charge r duite Lorsque l appareil est teint placer le levier de com...

Page 22: ...gistre d air de combustion tout fait N alimenter qu avec de petites quantit s de combustible Attiser souvent la cendre Habillage Il ne faut pas surchauffer l habillage car on pourrait vo quer des craq...

Page 23: ...tion Num ro de s rie 28 __________ Num ro de fabrication ________________________ Que faut il faire si le po le ne tire pas bien La chemin e ou le tuyau de chemin e ne sont ils pas tanches La chemin e...

Page 24: ...78 4628 9151 R 01 08 2019 Olsberg GmbH H ttenstra e 38 59939 Olsberg T 49 2962 805 0 F 49 2962 805 180 info olsberg com olsberg com...

Reviews: