You may avoid inconvenience and service calls by checking these points before you call for service.
Possible Cause
What to do
Thermostat is not set correctly Reset thermostat above room temperature
Burner is not operating properly Check flame. If it is yellow, burner is not getting enough air.
Or, if flame is blue and noisy and seems to lift off burner,
burner is getting too much air. Contact your service technician.
No electric power to boiler
Check over current protection. Verify electric power supply circuit is
“ON”.
Controls out of adjustment
Reset according to instructions.
Radiators not heating
Open radiator vents to expel air. Check flow control valve (if
used). It may be in closed position.
Circulating pump not running Check over current protection. Check relay operation.
Poor electrical contact
Check all control terminals and wire joints.
Rollout switch blown
Have your service agent check heat exchanged for blockage.
Replace rollout switch with exact replacement.
Blocked vent blown
Have your service agent check venting system and chimney
for blockage, or down draft condition. Reset blocked vent.
Vent damper not operating
Consult troubleshooting guide in Effikal manual, packaged with
vent
damper.
Possible Cause
What to do
Gas input amount is incorrect Contact your service agent.
Possible Cause
What to do
Dirt on seat
Open valve manually. Allow water to run and clear valve seat.
Water logged expansion tank Drain tank, see instructions.
IF YOUR SYSTEM IS NOT HEATING OR NOT GIVING ENOUGH HEAT . . .
IF BURNER IS NOISY . . .
RELIEF VALVE LEAKING . . .
HAVE YOUR SERVICE AGENT CHECK ANY PROBLEM YOU ARE UNABLE TO CORRECT.
CAUTION
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
•
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
•
If you cannot reach your gas supplier, call the fire
department.
!