Mid Rafter
Plywood
3 - 2 1/2” Screws angled
into each Mid Rafter.
46.
Inside the shed, position
4 - 90° Metal Brackets
onto the Roof Plywood
and outside Rafter and secure with
4 - 1 1/4” Screws
each. Complete for
both Gables.
Hardware
90° Metal Bracket
x 8 total
1 1/4” Screws
x 32 total
47.
To further secure Roof Panels, from the inside, drill pilot holes in each
Mid Rafter (3 per Rafter) on an angle. Using
3 - 2 1/2” Screws
, secure
Rafters to Roof Plywood.
Note:
from outside, have a helper push Roof Panel
down so Plywood sits flush against Rafter when securing.
Hardware
2 1/2” Screws
x 18 total
45.
Slide in another
Filler Shingle
and attach as
per
Step 44
. On your last row of Shingles, attach
smaller
Filler Shingles
with
2 - 1 1/2” Shingle
Nails
near the top, to be covered by
Ridge Caps
in
Step 66
. Complete all rows of
Filler Shingles
where roof seams meet in the same way.
44.
Screw first
Filler Shingle
down to Rafters
using
2 - 2 1/2” Screws
(1 per panel). Make
sure to screw into both Rafters.
Attach above
the exposure
line.
Exposure
Line
4 - 90° Metal Brackets
per Gable.