IMPORTANT
In the interests of safety please read these
instructions carefully before installing or
operating your new stove. Even if you have
installed or operated stoves before
manufacturer’s requirements can vary and can
also change with updates to building
regulations. If you are installing this stove in a
UK Smoke Control Area the Gabriel Inset can
only be fuelled with approved smokeless fuels
– it will be illegal to burn wood in it
.
STANDARD FEATURES
1 Primary Air Control
Air which enters under the
grate for multi fuel burning and to help get a wood
fire started
2 Secondary Air Control
Air which enters at the top
of the fire chamber to ensure a cleaner burn and
effective wood burning (pull out to open)
3 Airwash System
Part of the secondary air control
system which diverts hot air down along the front of
the glass to burn off unwanted sooty particulates and
help keep it clean
2
3
1
3
TECHNICAL DATA
General Specification
Model Name
Gabriel
®
Inset
Model Number
OL357i
Dimensions (mm): Facia H
605
W
490
D
95
Dimensions (mm): Firebox Ext H
515
W
380
D
175
Net Weight
83 kg
Gross Weight (packed)
95 kg
Data from CE Test EN13240
Fuel
Mineral Fuel & Wood Logs
WOOD
Nominal Heat Output
4.9 kW
Test Duration (approx)
1.02 hrs
Efficiency (net)
75.2%
Mean CO Emission (at 13%)
0.15
Mean Flue Gas Temperature
302ºC
Flue Gas Mass Flow
4.8 g/s
ANCIT (mineral fuel)
Nominal Heat Output (wood)
4.8 kW
Test Duration (approx)
3.99 hrs
Efficiency (net)
68.3%
Mean CO Emission (at 13%)
0.21
Mean Flue Gas Temperature
312ºC
Flue Gas Mass Flow
6.3 g/s
Minimum Distance to Combustible Materials
Top (shelf)
600 mm
Sides
250 mm
Flue
Flue configuration
top only
Flue pipe / liner diameter
150 mm (6”)
Minimum flue height
from base of stove
4500 mm (15’)
Wood Fuel Requirements
Wood Logs: Moisture content
<20%
Maximum Log Length
250 mm