Vareo MO W+R
Mounting instructions for installers
Important:
Read these instructions thoroughly before
installing the appliance. Determine the precise position in
the salon with the salon owner and the installation
specialist.
•
The wash unit is intended for operation in clean and
dry rooms at normal room temperature.
•
In the water supply system only original components
supplied by the manufacturer must be used.
•
The wash unit must only be connected to a water
supply where the supply pressure does not exceed
20 bar (20 MP a).
•
The new set of hoses supplied with the unit must be
used. Old hoses must not be used.
•
Observe minimum power socket spacing specified in
DIN VDE 0100 and VDE 0100 Part 701.
•
Ensure that the height of the drain and installation
shaft is correct.
1.
The water supply pipes to the wash unit must be
equipped with an “Aqua-Stop” system.
2.
Install the supply water and waste water lines as
shown in
Fig. 3.
Mounting instructions for appliance fitters
3.
Detach the backrest cushion (1):
Pull the backrest upwards and remove. On the vibro-
massage model, disconnect the 4 cables from the
adapter cables which lead to the control box.
4.
Detach the seat body (2):
Only slacken the 4 wing screws (3) underneath the
seat. Remove the 2 hexagon socket bolts (4)
(connection between seat and frame).
Detach the element connecting the seat to the leg
rest (6).
Pull the seat together with the armrests upwards and
remove.
5.
Prepare the cover section (7) for connection of the
installation tunnel:
Cut out a 140 mm dia. section as shown in
Fig. 2
.
Make sure that the mounting side corresponds to
that shown in the installation diagram
6.
Align the substructure (9) according to the
installation template and secure to the floor.
6 anchor bolts M 10 x 125 (extending 30 mm above
the finished floor) or metal plugs with metric thread
for hexagonal screws M 10 x 60.
Mounting instructions for installers
7.
Make sure that pipes/pressure hoses are parallel.
Connect the unit. Fit 40 mm dia. waste water pipe and
R ½" pressure lines with stop taps between the wall
and unit.
Prevent the stop valves from turning
while they are being screwed on
. Connect the
waste water hose to the siphon using a seal and union
nut. Insert the waste water hose at least 3 to 4 cm into
the siphon. Connect the drain bushing to the waste
water hose using a hose clamp.
8.
Close the mixing tap. Open the stop valve and check
for leaks with the mixing tap closed. Check the mixed
water. The hot water and cold water supply must
correspond to the coloured symbols on the mixing
tap.
9.
Check the pressure of the unit with 8 bar water
pressure. Then set the pressure to 3 to 5 bar. On
completion of the installation work, always rinse out the
water pipes. A central regulating tap is required if more
than one unit is installed. This tap must be easily
accessible from the salon.
These mounting instructions apply to the connection
of one unit.
If more than one unit is to be installed, the pipe
cross section must be increased accordingly.
Important:
If the water pressure is above 5 bar, it must be
regulated by a pressure reduction valve. Since a pressure
reduction valve is used for boilers, such a valve can be fitted
along the common water supply line.
Note for salon owners:
The connections described under points 1 and 6 to 9 must
be performed by the installer. The installer is responsible for
any problems that may occur. The manufacturer of the unit
shall not accept warranty claims for this work.
Mounting instructions for appliance fitters
10.
Secure the side cover sections (7) to the unit using
Velcro tape. Attach 2 angle brackets for the installation
tunnel to side (
Fig. 2
) and wall (
Fig. 3
).
Caution:
fit angle brackets inside the installation
tunnel.
GB