The display shows:
1234567890123456
The cursor blinks over the ‘1’ digit . If we want the relay to be activated by lets say
zones 1,2,3,4,5 and 6 press the’1’ key (yes) 6 times. The cursor is moved 6
positions to the right and is positioned over the ‘7’. Press the ‘2’ key (no) 10 times
and the display will show:
1234567890123456
Pressing ‘ENTER’ will activate the selection. The relay will only be activated when
one of the preselected zones (ticked) issues an alarm. We can also adjust the
operation time and the time to operate delay as described earlier.
ACTIVATE FROM
TWO ZONES (AND)
4.
The relay is activated when 2 preselected zones issue an
alarm .If this method of activation is selected the by
pressing ‘ENTER’ we must select the desired zones on
the next menu.
The Display shows:
1234567890123456
The cursor blinks over the ‘1’. If we want the relay for example to be activated
by zones 5 and 6 the press the ‘2’ key for 4 times. The curcors shifts 4 places to the
right and is positioned over the ‘5’. Press the ‘1’ key (yes) 2 times and the display
shows:
1234567890123456
By pressing ‘ENTER’ the setting is activated . The relay will be activated only if both
zones 5 and 6 issue and alarm. We can also adjust the operation time and the time
to operate delay as described earlier.
The second device that can be programmed is the FAULT relay.
We select it by pressing ‘ENTER’.
CONFIGURE
FAULT RELAY 1
ACTIVATE FROM
GENERAL FAULT
After ‘ENTER’ is pressed the activation method is
shown.(default=GENERALl FAULT) If we want to
alter the activation method we must follow exactly the same procedure as
described earlier for the programming of the ALARM relay. The options and
settings are identical.
CONFIGURE
SIREN 1
ACTIVATE FROM
GENERAL ALARM
We can also program the siren output. We can
select using the ‘ FAULT EVENTS’ key
Select the required output using the numeric keypad and by pressing ‘ENTER’ we can se
e
it’s
activation method (default=general ALARM). If we want to change the activation method press
the ’FAULT EVENTS’ key and ‘ENTER’. The options available are. “ACTIVATED BY GENERAL
ALARM” and “ACTIVATED BY ZONES(OR)”. The functions of the setting are the same as
described earlier for the ALARM relay. With the option “DURATION” we can select if the output
will have a permanent or an interruptible operation. The settings are the following:
0= permanent operation
1 = interruptible operation with 3 seconds ΟΝ - 5 seconds OFF
15
from