11-4-2017
13
921468001_09_015
All zones are on the same section and the system arms and disarms all together. On zone 1 the
magnetic trap activated the bell on the keyboard to warn us that the door has opened.
2. Zone 1 : Zone with delay
section
Α
Zone 2 : Zone with delay
section
Β
Zone 3 : Zone without delay
section
Β
Zone 4 : Zone without delay
section C
Zone 5 : Zone without delay
section C
Zone 6 : Zone without delay
section
Α
Zone 7 : Zone without delay
section
Α
Zone 8 : TAMPER zone
Zone 17 (keyboard 1) : Zone with delay section
Α
This pre-made program is suitable for a 2-story house. Connect to zone 1 or to the zone of the
keyboard the entrance magnetic contact. On zone 2 the radars that monitor the entrance area. On
zone 3 the remaining radars of the ground level floor, on zones 4 and 5 the radars of the first floor and
on zones 6 and 7 the magnetic contacts of the ground floor and the first floor respectively. Finally
connect the TAMPER of the external siren to zone 8. By arming section A we have a parametric
alarm, with the arming of section A and B we have a parametric alarm with the simultaneous operation
of the ground floor radar detectors and if we arm sections ABC we have full operation of the system.
3. Zone 1 : Zone with delay
section
Α
With bell sound
Zone 2 : Zone with delay
section
Α
Zone 3 : Zone without delay
section
Α
Zone 4 : Zone with delay
section B
Zone 5 : Zone with delay
section B
Zone 6 : Zone without delay
section B
Zone 7 : Zone without delay
section B
Zone 8 : TAMPER Zone
Zone 17 (keyboard 1) : Zone with delay section
Α
This pre-made program is suitable for a house-store combination using the same alarm panel and the
same siren. Connect on zone1 or on the keyboard zone the magnetic contacts of the store entrance.
On zone 2 the radars that monitor the entrance area of the store. On zone 3 the remaining radars or
magnetic contacts of the store. On zone 4 the magnetic contact of the house entrance, on zone 5 the
radars that monitor the entrance of the house and on zones 6 and 7 the remaining radars and
magnetic contacts of the house. Finally on zone 8 connect the TAMPER of the external siren. By
arming section A we have an alarm system only for the store, by arming section B we have an alarm
system only for the house and by arming section ABC we have an full alarm system for both the store
and house.
4. Zone 1 : Zone with delay
section
Α
Zone 2 : Zone without delay
section
Α
Zone 3 : Zone without delay
section
Α
Zone 4 : Zone without delay
section
Α
Zone 5 : Zone without delay
section
Α
Zone 6 : Zone with delay
section B
Zone 7 : Zone without delay
section B
Zone 8 : TAMPER zone
Zone 17 (keyboard 1) : Zone with delay section
Α
Summary of Contents for BS-468
Page 1: ...BURGLAR ALARM PANEL BS 468...