zone. The zone is regarded again by the system when it stops being active ( i.e. when the window
closes). If we select NO and the zone during the arming process is active (i.e. open window) and the
automatic bypass has been selected, the system will warn us that the arming is not possible.
For the last three setting if we select ZONE MODE the panel will automatically select the correct
setting. If no special setting are require then it is good practice to no alter these.
Output programming
The next setting of the technician menu is
«OUTPUT». Via this
setting we can program how each of the outputs
Ρ1, Ρ2, Ρ3 and
RELAY will operate. When an output is activated we mean that it
has 12V or the relay has been activated. When an output has been
deactivated it has 0V and the relay is in the idle state.
If we press (*) select the output and press again the (*) key we are
presented with the following options:
«DISABLE OFF». The output does not operate
«LIKE SIREN». Activates the external siren (via the START terminal) with positive logic. It has 0V in
the idle state and 12V in alarm. By default this is how the P1 output is programmed.
«ON ALARM». It is activated when we have an alarm on the zone which has been programmed like:
ZONE WITH DELAY.
ZONE WITHOUT DELAY.
ZONE NEXT DELAY.
TAMPER
RADAR 2 PULSES.
«ON FIRE». It is activated when we have an alarm from a FIRE zone.
«ON PANIC». It is activated when we have an alarm from a PANIC zone.
«ON FAULT». It is activated when we have any fault.
«ON ARM». It is activated when the panel is armed.
«FLASH». It produces 3 short pulses during the arming of the panel and one long pulse during the
disarming. It can be connected to the FLASH or FL of the external siren. It is useful if the system is
control by remote control. By default the output P3 is programmed with the function.
«ON OFF MANUAL». It is activated manually by the keyboard of by a zone that has been
programmed as PG CONTROL. By default the output RELAY is programmed like this.
«AC STATUS». It is activated in the event of an AC power supply failure.
«SUPPLY FIRE DETECTOR». It is suitable for powering smoke and heat detectors. It has a
permanent voltage of 12V which is disrupted for 5 seconds after every disarming. By default this is
how the output P2 has been programmed.
«ΟΝ SILENT ALARM». It is activated when an alarm has been issued by the SILENT zone.
Programming the general parameters of the system
The next selection in the technician menu is
«SYSTEM». Via this selection we can adjust various
parameters f the system:
«DEVICE ADDRESS». Change the address of the keyboard. By default each keyboard BS-466 has
address 2. If we only have one keyboard there is no reason to change the address. If we have more
that 1 keyboard, each keyboard must have its own address in order to be acknowledged by the panel.
«SCAN KEYBOARDS». If we press (*) the system scans for all connected keyboards and shows then
on the display.
«SCAN EXTENSIONS». If automatically detects the expansion cards. It must be used every time that
we connect one of the expansion cards such as the zone expansion card, GSM telephone dialer or
PSTN telephone dialer.