2. Instructions for the user
2.1Basic operations
The panel has 1 main code (master) which by default is set to [1 2 3 4] and up-to 50 user codes which
by default are not programmed. The system can operate with two different modes. Depending on the
mode of operation, the arm and disarm operations differ.
Complete system.
In this case the system arms and disarms altogether
The arming
can be done by using the master code or one of the user codes. The arming of the
system can also be done by simply pressing the ABC key during the installation if the option
«one key
arming
» has been selected.
The disarming
can be done by entering the master code or one of the user codes.
Split system.
In this case the system operates as three independent subsystems.
You can arm
and disarm the whole system or each subsystem independent from the others.
The arming of all the system
can be done by using the master code or one of the user codes that
have been programmed for general arming. The arming of the system can also be done by simply
pressing the ABC key if during the programming the option
«one key programming» has been
selected.
The disarming of the system
can be done by using the master code or one of the user code that
have been programmed for general disarming.
The individual arming of the subsystems
Α,Β,C
can be done by pressing one of the user codes
that have been programmed to arm each subsystem. The arming can also be done by pressing one of
the
Α, Β or C keys if during the programming «one key arming» has been selected. The arming of one
subsystem does not affect the status (armed-disarmed) of the other subsystems.
The individual disarming of the subsystems
Α,Β,C
can be done by pressing one of the user codes
that have been programmed to disarm each subsystem. The arming of one subsystem does not affect
the status (armed-disarmed) of the other subsystems.
If during the arming procedure a zone is active then the keyboard show the message:
Which means that on zone 5(kitchen) a window has been left open.
If we press (#) the arm command is canceled.
If we press (*) or close the kitchen window we see:
This message is shown for 1 second and immediately the arming
process starts.
SYSTEM CAN NOT ARM
ZONE 05
KITCHEN
*:
BYPASS ZONE
#:
CANCEL
ZONES BYPASSED
READY TO ARM
Summary of Contents for BS-468