Selecting
«LAST ALARMS» we can view the alarms that were registered during the last arming of the
system. The display will be like the one below:
This means that an alarm was registered for zone 8 which is a
TAMPER zone (24 hour operation). The alarm was issued on 12:20
on 07 March 2012 and that is the first of 3 events.
Using the up and down arrows (2 and 8) we can view all the
registered alarm events.
Selecting
«ALL EVENTS» we can view all the events which are registered in memory. The display will
be like the one below:
This means that an error event was registered for zone1 at 12:20
on 07 March 2012. It also informs us this is the 70
th
event of a total
to 70. With the up and down arrow keys (2 and 8) we can see all
the registered events.
The event memory has a capacity of 250 events and once filled will
erase the oldest. The events that are registered are errors, alarms,
user and technician menu access as well as the arming and
disarming of the system. The main user and the technician can
both erase the events memory using there respective menus.
Selecting
«MANUAL OUTPUTS CHECK» we can see:
With the up and down arrow keys we can select the required option
and by pressing (*) we can see or we can change the state of the
output
Ρ1, Ρ2, Ρ3, RELAY.
Warning.
In order for an output to be able to change state from this
selection it must be programmed as
«ON OFF MANUAL». When an
output changes state, the device connected to it is activated. A
manual change of the output sets the output to a permanent
condition which can only change by manually changing the output
again. It is suggested to use this selection with caution and only if
we want to manually control a connected device.
Selecting
«INFORMATION» we can see:
With the up and down arrow keys we can make the selection and
by pressing the (*) key we can view the keyboard firmware version,
the panel firmware version, the information regarding the technician
supporting the system and the signal level (If a GSM is connected)
The selection
«TECHNICIAN INFO» by default has information of
Olympia electronics.
TAMPER
ZONE 08
ΖΟΝΕ 8
07/03/12 12:20
001/003
ERROR
ZONE 01
ΖΟΝΕ 1
07/03/12 12:20
070/070
_MANUAL OUTPUTS CHECK _
CHANGE OUTPUT
OUTPUTS STATUS
______INFORMATION______
KEYBOARD SOFT VERS.
PANEL SOFT VERSION
TECHNICIAN INFO
SIGNAL LEVEL