KEYS UNLOCK AFTER DEVICE ACTIVATION

KEYS UNLOCK AFTER DEVICE ACTIVATION

EXAMPLE OF 

ENTRANCE

 CODE (

SYSTEM DISARM)

EXAMPLE OF 

ENTRANCE

 CODE (

SYSTEM DISARM)

Assuming the disarming code is 1234, then to disarm the system, 

just

 touch 

with 

y

our 

palm 

the keys and once the keys 

are 

illuminated, press "*" then "1234".

Communication error:

 If the message "

COMMUNICATION 

ERROR 

WITH THE 

PANEL

" is printed at startup

,

 

t

his means either the keyboard is not connected to 

any network, or it cannot communicate with the 

control 

panel for some reason.

AUTOMATIC 

ADJUSTMENT

 OF SENSITIVITY LEVEL

AUTOMATIC 

ADJUSTMENT

 OF SENSITIVITY LEVEL

DEVICE DEACTIVATION

DEVICE DEACTIVATION

If the keyboard does not detect a human 

palm

, it will 

power down

 after 10 

seconds 

in order to save power.

 

 

I

n this 

state 

only 

the following 

functions are 

active

a) tamper

 detection

 

b) 

external contact

 detection

c) 

detection of the human 

palm

 near the keys

.

 

The reasons which cause the

 device 

to

 remain 

activated

 

for more than

 10 

seconds are described in the 

Device Activation

” paragraph

.

Energy

 sav

ing

:

 If the keyboard does not detect the human 

palm

 over the 

keys

 

for 10 seconds, it turns off the 

LCD 

backlight of the screen and the keys, even if 

it remains on, so it saves energy.

When the device is 

deactivated, a

 t

ouch to the buttons with the palm of the hand 

for 1 second is needed

 

in order to activate

 

the device

. As soon as 

the device

 is 

activated

, the LCD screen and the 

backlight

 of the keys are 

lighting

. At this 

stage, the keys are locked, and 

every

 three seconds a message 

appears 

prompting 

the user

 to press the 

*

 key 

so as 

to unlock the keypad. Until this 

button is pressed, no other button will be activated even if 

it is pressed

, and the 

buzzer will not sound when the buttons are pressed. 

As soon as

 we press 

*

the keypad is unlocked and the buzzer will now sound when a key is pressed. 
When the keypad unlocks, the symbol

 

(

)

 

on the screen briefly shows that the 

keypad has been unlocked.

IMPORTANT : 

The panic key is detected even if the keyboard is locked. So 

the user will not have to push the “*” key, instead can directly push the “#” 
key for 5 sec. after device activation, in order to send the panic alarm.

Once the batteries are installed, the device detects the surrounding area and 
gradually adjusts the sensitivity of the keys. In this case, after installing the 
batteries, it is likely that the device will remain 

activated

 for more than

 

10 

seconds. Also in the event of a significant change, such as being removed from 
the wall and held in the user's hand, the auto

matic adjustment

 process is 

intensified and the device is likely to remain 

activated

 for more than 10 seconds.

Due to the above, it is suggested during the installation process that the user 
should hold in his/her hand the complete device (the keyboard mounted on the 
base). Over time the surface of the device will cause any accumulation of dust or 
moisture. The process of automatic sensitivity adjustment is quite important 
because the device will cope as well as possible with these changes.

Summary of Contents for BS-477

Page 1: ...OF COVER PROTECTION PRODUCED IN ACCORDANCE WITH COMPLIES WITH OPERATION TEMPERATURE RANGE CONSTRUCTION MATERIALS DEVICE DIMENSIONS LxWxH TYPICAL WEIGHT GUARANTEE 2 years ο 10 to 40 C COMMUNICATION FREQUENCY COMMUNICATION RANGE 868 MHz About 200m open area ABS PC 205gr 150 6 x 100 6 x 30 6 mm EN 50131 1 CLC TS 50131 2 2 EN 50131 5 3 classification grade 2 ETSI EN 300220 EN 50130 4 EN 55022 EN 60950...

Page 2: ...l has been read To install follow the procedure below 1 Remove the front cover of the device with a wide screwdriver 2 Mount the rear plastic to the wall with the supplied mounting materials to the points shown in Figure 2 When an external input connection is required connect to the terminal block of the base 3 Insert the batteries into the device and re install the front cover that was removed in...

Page 3: ... or code to enter menu is entered LED INDICATIONS LED INDICATIONS CONTROL KEYS CONTROL KEYS DEVICE ACTIVATION DEVICE ACTIVATION Power supply ok System ready to arm Sector A armed Sector B armed Sector C armed When LED is on means that there is fault When blinking means that alarm is activated Note During exit countdown Sectors indicators blink by default B C A 0 9 Entry numbers Menu entry Enter Ca...

Page 4: ...activated the LCD screen and the backlight of the keys are lighting At this stage the keys are locked and every three seconds a message appears prompting the user to press the key so as to unlock the keypad Until this button is pressed no other button will be activated even if it is pressed and the buzzer will not sound when the buttons are pressed As soon as we press the keypad is unlocked and th...

Page 5: ...rves the right to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R Thessaloniki Katerini P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics gr info olympia electronics gr WARRANTY WARRANTY The wireless keyboar...

Reviews: