BS-506/ALKALINE
Olympia Electronics guarantees the quality, condition and operation of the
goods. The period of warranty is specified in the official catalogue of Olympia
Electronics and also in the technical leaflet, which accompanies each product.
This warranty ceases to exist if the buyer does not follow the technical
instructions included in official documents given by Olympia Electronics or if the
buyer modifies the goods provided or has any repairs or re-setting done by a third
party, unless Olympia Electronics has fully agreed to them in writing.
Products
that have been damaged can be returned to the premises of our company for
repair or replacement, as long as the warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods
and to or not
charge the buyer depending on the reason of defection. Olympia
Electronics reserves the right to charge or not the buyer the transportation cost.
Thank you for your trust in our products
Olympia Electronics - European manufacturer
921506000_09_005
Warranty
4
5
European
manufacturers
72
nd
km
.
O
.
N
.
R
.
Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.com
info@olympia-electronics.gr
Signaling Overview
1 Red per 344 sec
None
Device
functioning properly
1 Red per sec
Alarm pattern
Device under test
1 Red per sec
Alarm Pattern
Smoke detected
1 Red per 10 sec
None
9 min
decreased sensitivity
3 Yellow per 43 sec
None
Exited an
alarm mode
None
Replace batteries
None
3 short signals
per 43 sec
Replace the
smoke detector
1 short signal
per 43 sec
ALARM
TEST
HUSH
ALARM MEMORY
LOW BATTERY
FAULT WARNING
NORMAL
1. Remove smoke alarm from mounting plate following Step 1 of the
installation instructions.
4. Place the smoke alarm on the Mounting plate and secure it by turning it
clockwise.
3. Replace the old batteries by a new pair. Use recommended batteries for
more reliable operation.
2. Clean the device as described in maintenance paragraph.
5. Test the correct operation of your smoke alarm as described in Device Test
paragraph. If no sound is generated, the smoke alarm must be replaced
immediately!
The WEEE symbol means that this product and batteries must be disposed
separately from other household waste. When they reach their end of
life, take them to a designated waste collection point in your area to
guarantee a safe disposal or recycling. Protect the environment, human
health and natural resources!
False alarm is often caused by dust or steam.
After a batteries replacement, the device performs an auto-adjusting process
in 8 hours period to establish its operation. If false alarm happens within this
period, it is important to clean the smoke alarm as described in maintenance
paragraph.
Battery Replacement
Recycling and Desposal
Troubleshooting
921506000_09_005
Visible indication
(flashes)
Operating Mode
Acoustic Signal
Comment
BS-506/ALKALINE
7 years
Technical Characteristics
0.110 dB/m
Optical and Acoustic > 85dB (A) at 3 m
Yes
Yes
Yes
Ceiling
No
Optical
IP20
EN14604-2005
o
0 to 45 C
Up to 93%
ABS/PC, PC
Ø130 x 43 mm
185gr.
3 years
(1
year for the battery
)
SMOKE CONCENTRATION SENSITIVITY
INDICATORS
ALARM SILENCE FACILITY
LOW BATTERY WARNING
LOW BATTERY SILENCE FACILITY
MOUNTING LOCATION
INTERCONNECTABLE
DETECTION METHOD
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
DEGREES OF COVER PROTECTION
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION
WEIGHT
GUARANTEE
POWER SUPPLY
BATTERY LIFE
Replaceable batteries: 2x Alkaline AA (LR6)
IP
20
7 years
Optical
85dB
EN14604
2005
Battery
Life
BATTERY OPERATED
SMOKE DETECTOR
BS-506/ALKALINE
Battery Operated
Smoke Detector
1922
21
EN
14604:2005
DoP: 921506000_59_001
EGINIO
PIERIAS
60
300
GREECE