Extended battery life (>3 years).
3 operation modes: manual, daily, weekly.
Easy operation via 8 keys.
Easy programming.
Multi function LCD with backlight.
Clock, calendar.
Keyboard lock.
Upper and lower limit settings.
Manual temperature selection.
Boiler option (BS-813/A) with adjustable time.
Heating and cooling function.

Thank you for your trust in our products 

Olympia Electronics -  European manufacturers

940812001_09_001

.Thermostat active indicator

.Increase value
.Decrease value

DESCRIPTION  OF  CONTROLS  - 
INDICATORS

.Battery status indicator

.Thermostat activation key

 

= when the selection is smaller that the 

actual temper 

  

   = When the selection   the differential is 

+

greater than the actual temperature.
           = When the temperature is in the range 
between the selection and the sel the 
deferential.

.Presence indicator

.Thermostat deactivation key

.Thermostat inactive indicator

.Temperature rise or fall indica t o  r

9

Go to the previous value or selection

Weekly program indicator

Day indicator

Burner activation indicator

Temperature and message display

 

Presence program selection indicator

Cancel/exit from selection

Boiler activation / deactivation (valid 

Hour and message display

 

.

 Burner active indicator

  only for BS-813/A)

Temperature unit display

Go to the next selection or value

Select normal or night program

Select and confirm installation settings

Daily program indicator

Manual program indicator

Night program indicator

Normal program indicator

Boiler activation indicator

17

18

19

20

21

22

23

24

25

26

27

28

The key         is like this         on the BS-812/A,BS-814/A.

BATTERY OPERATED PROGRAMMABLE 

CHRONO - THERMOSTATS IN ANTHRACITE COLOR

BATTERY OPERATED PROGRAMMABLE 

CHRONO - THERMOSTATS IN ANTHRACITE COLOR

 

BS-812/A,BS-813/A,BS-814/A

BS-812/A,BS-813/A,BS-814/A

ESC

MENU

ENTER

1

2

3

4

5

7

8

9

10

12

14

11

6

13

20

19

18

17

16

15

21

23

24

26

27

28

25

22

Summary of Contents for BS-812/A

Page 1: ...ce indicator Thermostat deactivation key Thermostat inactive indicator Temperature rise or fall indicator 9 Go to the previous value or selection Weekly program indicator Day indicator Burner activation indicator Temperature and message display Presence program selection indicator Cancel exit from selection Boiler activation deactivation valid Hour and message display Burner active indicator only ...

Page 2: ...the absence command was issued GENERAL When the plastic battery separator found between the two batteries is removed then the device is activated and all the symbols are shown on the LCD for 1 immediately follows a number that corresponds to the firmware version and then the initial screen In the middle of the screen we can see the current temperature The clock shows 00 00 the date is 1st January ...

Page 3: ...een with the blinking With consecutive presses of the key we can select the remaining programs in the 24 hour base 10 in total and to determine the required times and temperatures as described above Please note that for every program we determine only the start time since the end time is the start time of the next program For example if we require a temperature of 23 0 ºC from 14 00 to18 00 in pro...

Page 4: ...ht of the screen Β Unit TEMPERATURE UNIT Depending on the selection the symbol ºC or ºF are shown on the center right of the screen With this setting we can turn off the screen illumination in order to conserve battery energy If ΟΝ is selected then the screen illumination will be activated every time a key is pressed If is selected then the screen illumination will be deactivated D LED BURNER OUTP...

Page 5: ...electing the device can control heating units e i diesel burners whereas with the selection it can control cooling units e i air conditioners I Time HOUR METER If for any reason there is the need to restore the thermostat to its factory default settings then this setting will restore then is we select and press the key Night program Night Manual program User Upper limit High Temperature Limit for ...

Page 6: ... 5 Press the key and we return to the previous screen with the blinking 3 Press the key 9 times and the screen shows with the Mode blinking has a 10 program capability 15 Completing the daily program we can store the programmed values to the devices memory by pressing 2 times the 9 Press the key and the minutes digit starts to blink With the keys select 00 12 Press the key and the symbol will blin...

Page 7: ...with the indication blinking By pressing the key the day indicator changes to TU Τuesday and we can repeat the steps for programming a new program for Tuesday The same can be done for the rest of the days of the week 5 The completion of the weekly programming can be done by pressing the key when the indicator is blinking The screen will show the message briefly and the settings will be stored in t...

Page 8: ...s and remove the plastic cover containing the keys photo 3 3 Use the supplied support screws and plugs after opening the required holes on the mounting surface photo 1 Install the base and align using the built in alignment vial Tighten the retaining screws 4 Press and remove the pre etched cable entry photo 1 Perform the connections as shown in the diagrams on page 8 THE NEUTRAL IS NOT CONNECTED ...

Page 9: ...ns Electrical connections The installation MUST be performed by an authorized electrician Otherwise the warranty will be invalid For new installation a third wire for neutral N is not required 2 wire connection The installation MUST be performed by an authorized electrician Otherwise the warranty will be invalid Neutral blue wire Ν IS NOT CONNECTED Live Brown wire L Neutral blue wire Ν IS NOT CONN...

Page 10: ... technical instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re setting done by a third party unless Olympia Electronics has fully agreed to them in writing Products that have been damaged can be returned to the premises of our company for repair or replacement as long as the warranty period is valid Olympia E...