A. (Mode) OPERATION MODE.
9. SELECTING THE UPPER AND LOWER
L I M I T S O F T H E M A N U A L
TEMPERATURE ADJUSTMENT
(the
thermostat is in the OFF state).
After entering the MENU use the key to
select the required setting. The messages
are shown in the bottom section of the
screen like this:
One of three operation modes can be
selected:
day else the factory default temperature of
23.0 ºC will be used for all the 24 hour base.
After entering the MENU and by
consecutive presses of the key the
message (High Temperature Limit) will
be shown on the bottom of the screen
as well as the initial value 30.0 ºC. By
pressing the key we can change this
temperature between the lower limit
and the value of 30.0 ºC. By pressing the
key and then immediately the key
the lower section of the screen shows the
message (Low Temperature Limit) as
well as the initial temperature of 6.0 ºC. With
the key we can adjust the value
between 6.0 ºC and the value of the upper
limit. The two limits define a temperature
area that can be used by the user to enter
the desired temperature. The selection of
the limits influences the manual adjustment
of the temperature and is independent from
the operating mode of the unit (manual,
daily weekly) and does not have any
influence on the programs for daily or
weekly operation.
10.OTHER MENU SETTINGS
(the
thermostat is in the OFF state).
(User) Manual mode (the symbol
ΜΑΝ
. is shown on the top right of the
screen).
The option are: or (Degree
Celsius ή Degree Fahrenheit) and regard
the display of the temperature in ºC or ºF.
The factory default is .
(Day) daily operation (the symbol
DAY
is shown on the top right of the screen.
.
(7 Days) weekly program (the
PPPP
symbol
WΕΕK
is shown on the top right of
the screen).
Β. (Unit) TEMPERATURE UNIT.
Depending on the selection, the symbol ºC
or ºF are shown on the center right of the
screen.
With this setting we can turn off the screen
illumination in order to conserve battery
energy. If (ΟΝ) is selected then the
screen illumination will be activated every
time a key is pressed. If is selected then
the screen illumination will be deactivated.
D . ( L E D ) B U R N E R O U T P U T
INDICATOR.
This setting can deactivate the burner
output indicator in order to conserve battery
energy.. If (ON) is selected then, when
the burner output is active, the indicator will
briefly blink every second so the user has a
knowledge of the state of the thermostat
from a distance.. If (OFF) is selected
then the indicator is deactivated.
Ε. (Time Out) TEMPORARY TIME
FOR MANUAL OPERATION.
With this setting we can determine the time
period for which the manual temperature
adjustment is valid. When the thermostat is
running a daily or weekly program and we
press the keys or then the
thermostat enters briefly the manual mode
for a time period that is determined by the
setting . The value of this setting can
be from 3 to 10 hours after which normal
program execution is continued. The
factory default is 3 hours.
F. (Differential) DIFFERENTIAL
SETTING.
C. (Back Light) SCREEN ILLUMI-
NATION.
This setting determines the
” temperature
w i n d o w ”
b e t w e e n a c t i v a t i o n a n d
deactivation of the burner output. For
example, if the thermostat is set to heating
and the room temperature is set to 23.0 °C
then with a differential of 0.5 °C the output to
the burner will be deactivated at 23.0 °C
and will be reactivated at 22.5 °C. If the
device is set to cooling mode then the
output will be deactivated at 23.0 °C and will
be reactivated at 23.5 °C. The differential
value can be set between 0.2 °C and 4.0
°C.
The factory default is .
The factory default value is 0.5 °C.
MENU
ENTER
ESC
MENU
ENTER
Page 4 from 10
940812001_09_001