control  heating  units  (e.i.  diesel  burners), 
whereas  with  the  selection                it  can 
c o n t r o l   c o o l i n g   u n i t s   ( e . i .     a i r -
conditioners).

H.          (Time) HOUR METER.

In this screen position we can see the total 
operation hours of the burner or the cooling 
unit. This  value  can  not  be  altered  by  the 
keypad  but  can  be  reset  if  the  battery  is 
removed.  the  maximum  value  is  9.999 
hours.

I.            (Factory settings)   
SELECTING THE FACTORY DEFAULT 
SETTINGS.

If for any reason there is the need to restore 
the thermostat to its factory default settings 
then  this  setting  will  restore  then  is  we 
select       and press the key      .This does 
not affect the time and date settings.
The factory default setting is        .

11. CHANGING THE BATTERY

When  the  screen  shows  the          symbol             
the unit warns use that the batteries have 
limited  energy  and  that  they  must  be 
replaced in the next 3 weeks. To replace the 
batteries simple remove the cover (Fig. 2) 
to  expose  the  battery  compartment. 
Remove  the  batteries  and  within  30 
seconds reinsert new ones in order to avoid 
a reset of the device. Should this happen it 
will  require  to  adjust  the  time  and  date 
again. All other setting remain unaffected.   
Avoid  replacing  the  batteries  with  the 
backlight  activated,  /this  will  immediately 
reset the device and the hour meter. Take 
care of the battery orientation and insert the 
new  batteries  according  to  the  graphic 
representation etched on the plastic base. 
The  reverse  installation  will  not  harm  the 
device but it will not permit it to operate.
The battery life time has been design to be 
approximately  2  years.  Factors  that 
influence the battery life are prolong use of 
the  keyboard  with  the  backlight  active, 
increased temperature and humidity as well 
as battery quality. 

12. ANTI-ICE PROTECTION

If  the  room  temperature  in  which  the 
thermostat is installed falls below  5°C, the 
unit activates the burner output irrelevant of 
the  ON  or  OFF  state  of  the  thermostat  to 
prevent ice build up. The burner output is 
active  for  as  long  as  the  temperature  is 
below 5°C.

13. CLEANING THE THERMOSTAT

To  clean  the  device  use  a  damp  cloth  to 
remove any dust or stains from the covers. 
Do not use any liquid or dissolvers that will 
damage the plastic covers.

14. SCREEN MESSAGES

Following  you  can  see  a  complete  list  of 
screen  messages  that  can  be  seen  by 
consecutively pressing the        key:
        = 

 =Time and date setting.

Set Time

 

 = Daily program selection.

       Day

  

   = 

 = Weekly program selection.

    

Week

         = 

 = Operation mode selection.

  Mode

         = 

 = Temperature unit.

  

Unit

      = 

 = Screen illumination.

Backlight

  

 = Burner output indication LED.

        LED

                   = 

 = Manual temperature 

Time out

time.
         = 

 = Upper limit 

High Temperature Limit

for manual temperature adjustment.
         = 

 = Lower limit 

Low Temperature Limit

for manual temperature adjustment.
         = 

 = Active boiler time

Boiler Time

         = 

 = Differential for burner 

Differential

relay.
          = 

 = Absence program.

Absent

          = 

 = Night program.

Night

   

 = Heat/Cold operation 

        Heat/Cold

mode.
        = RF=Wirelless connection setting
         = 

 = Factory default settings.

  

Factory

MISCELLANEOUS INDICATIONS

       = 

 = keyboard lock.

Lock

         = 

 = unlock keyboard.

 

  Unlock

       = 

 = Save settings to memory.

    Save

        = 

 = Manual program

    User

                 = 

 = Celsius temp. 

Degree Celsius

unit.
       

  =  Fahrenheit 

     

Degree  Fahrenheit

temp. unit.
         = 

= Program number 

Program 1 to 10 

from 1 to 10.

MENU

ENTER

940821001_09_001

Summary of Contents for BS-821/KIT

Page 1: ...819 T BATTERYOPERATEDWIRELESSPROGRAMMABLECHRONO THERMOSTAT WITHCOOLINGANDHEATINGFUNCTION BOILEROUTPUT BATTERYOPERATEDWIRELESSPROGRAMMABLECHRONO THERMOSTAT WITHCOOLINGANDHEATINGFUNCTION BOILEROUTPUT Th...

Page 2: ...ily programming example page 7 Weekly programming example page 8 Wireless communication settings page 8 communication errors page 9 Hour and message display Temperature and message display Temperature...

Page 3: ...e pressed simultaneously for 3 first the key and then the the screen will show the message and the keypad is locked Page 3 from 11 GENERAL When the plastic battery separator is remove the unit is auto...

Page 4: ...since the end time is the start time of the next program For example if we require a temperature of 23 0 C from 14 00 to18 00 in program 1 we will set the start time 14 00 at 23 0 C and the start time...

Page 5: ...his setting we can turn off the screen illumination in order to conserve battery energy If is selected then the screen illumination will be activated every time a key is pressed If is selected then th...

Page 6: ...erate The battery life time has been design to be approximately 2 years Factors that influence the battery life are prolong use of the keyboard with the backlight active increased temperature and humi...

Page 7: ...e blinking 4 Press the key and the starts to blink With the keys and we select the operation mode Day daily program 5 Press the key and we return to the previous screen with the blinking 6 Press the k...

Page 8: ...the key The weekly program will start to execute as defined In order for the program to execute correctly make sure you have programmed the device clock with the correct time WIRELESS CONNECTION SETTI...

Page 9: ...blink The interruption of the mains voltage causes the interruption of communication between the two devices When the voltage is restored the peripheral device receiver activates the outputs according...

Page 10: ...sure and the device is ready to operate Fig 4 POWER STATUS indicator N L 230V Boiler indicator Programming button 1 Boiler BS 821 R Burner Fig 5 A B Burner indicator To install the BS 821 R remove the...

Page 11: ...returned goods and to or not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R T...

Reviews: