OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
SENSOR CONSTRUCTION MATERIAL
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
(
main unit
/ +
sensor
)
GUARANTEE
OPERATION VOLTAGE
CONSUMPTION
(
only the device
)
OUTPUT POWER FOR THE FAN
OUTPUT POWER FOR THE CIRCULATOR
WATER SENSOR MEASUREMENT RANGE
SMOKE SENSOR MEASUREMENT RANGE
OUTPUT PROTECTION FOR BLOWER/CIRCULATOR
BLOWER POWER ADJUSTMENT
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
SENSOR CABLE LENGTH
TECHNICAL CHARACTERISTICS
220-240V AC/45-55Hz
0
-
100
%
o
o
-40 C to 120 C
Replaceable fuse
o
0-45
0 C
2
00 centimeters
for water: nickel-plated brass, for smoke: stainless steel
200W maximum
,85A
(
0
)
15
(
0 6
)
0W maximum
, 5A
3VA / 2,5W maximum
EN 60730-1, EN 60730-2-9, EN 61000-6-1, EN 61000-6-3
IP20
-
10 to
60
C
o
0 -
90% RH
2 years
275gr / 425gr
137
x 95 x 45 mm
940844002_09_00
4
Page
1 from
7
Programmable recessed thermostat for wood burners
with connection ability of two sensors
BS-84
4
/2
CONTROL AND INDICATOR DESCRIPTION
(1)
. ON/OFF button
(2)
.
Settings selection button
(3)
.
Decrease selected setting button
(4)
.
Increase selected setting button
(5)
.
LED information display
(6)
. Mains power indicator
(7)
.
Circulator operation indicator
(8)
.
Fan operation indicator
BASIC SETTINGS
When the unit is powered for the first time all the
indicators and the LED display are lit.
After that a
factory number is shown and the unit goes to a
standby state. The display shows
.
Here we can adjust the required setting
depending on the type of wood burner
.
To enter
the settings adjustment menu we must press
continuously the button for a few seconds until
the display shows the message
.
Immediately after pressing one of the keys (+) and
(-), the display will scroll all the programming
parameters of the device. When the desired
parameter is displayed by pressing the MENU
button the
initial value can be changed to the
desired value using the (+) and (-) buttons.
Whichever of the buttons (+) or (-) is pressed
constantly, changes the value quickly, not
requiring repeating presses.
If the MENU button is pressed again, the value is
stored in the device memory and the display
shows the name of the parameter that you just set.
Below are the programming parameters as would
occur if the button (+) is repeatedly after the
message is shown:
1. Circulator start temperature setting
The display shows the message
(
Circulator
Start
Temperature
)
.
Pressing the
MENU
button
will show the factory default setting which is
45
ºC
.
This value can be adjusted from
35–60
ºC
and sets
the water temperature above which the circulator
starts to operate.
If the water temperature is lower
then the selected value then the circulator does
not operate.
2.
Safety level temperature adjustment.
The display shows the message
(
Over
Heat
Limit
)
.
Pressing the
MENU
button will show the
factory default setting which is
85
ºC
.
This value
can be set between 86°C
and
9
5ºC and
determines the overheating level of the water.
If the water temperature exceeds this level then
the message (High
Temperature
)
is shown
,
and the buzzer is activated with an intermitted
sound.
Θερμοστάτης ξυλολέβητα
MENU
POWER
CIRC.
(6)
( )
7
(
8
)
(1)
(3)
(2)
(4)
(5)