FACTORY DEFAULT VALUES

The following values are the factory default 
setting of the thermostat:

Daily and weekly programs

 = 

Not set

Normal or Night program = 

Normal

Temperature unit 

=

 

Degrees Celsius

Selected temperature value 

=

 23.0°

C

Burner activation indicator 

=

 

Active

 (

On)

Presence/ Absence program = 

Presence

Upper manual temperature limit = 

30.0°C

Manual selection time 

hours

Lower manual temperature limit 

6.0°

C

Boiler  operation  time  = 

00  minutes 

(

BS-

851/T)

Operation mode

 = 

Manual

 (

User)

Differential = 

0.2° C

Screen backlight 

Active

 (

On)

Absence temperature 

16.0° 

C

Boiler state =

 Inactive 

(BS-851

/

T)

Thermostat state 

Inactive

 (

OFF)

Night program temperature = 

18.0° C

Note that the end hour of each program is 
the  start  hour  of  the  next  program  and 
always the start hour of a program is at least 
1 minute greater than the end hour of the 
previous program. It is essential to select at 
least  1  program  per  day  otherwise  the 
thermostat  will  operate  with  the  factory 
defined temperature of 6°C. Also note that 
the first program is considered the program 
with the start hour nearest to the hour 00.00  
(e.g. 07.00).

2. 

Press  continuously  the  key        for  3 

seconds  The screen back light is activated  

and the screen shows         . Now you are in 

 

programming  mode  of  the  thermostat 
parameters.

3. Press the key        9 times and the screen 
shows          with the         (Mode) blinking.

Heating function

Heating

1. Turn OFF the thermostat by pressing the 
corresponding key.

DAILY PROGRAMMING EXAMPLE

Lets assume that you want to program the 
following  temperatures  and  hours 
(programs): From 07.00 to 08.30 at 22,5°C. 
From 8.30 to 12.00 at 21,5°C. From 12.00 
to 17.30 at 18.5°C. From 17.30 to 23.00 at 
22.5°C and from 23.00 to 07.00 at 19,8°C.

Keypad state = 

Unlocked

select 07. 

14. Following the steps 8, 9, 10 and 11 to 
adjust  the  remaining  programs  with  the 
values  12.00/18,5°C,  17.30/22,5°C  and 
23.00/ 19.8°C. If by mistake you add a new 
program  (ex.  Ρ6),  this  program  can’t  be 
canceled  but  can  be  defined  as  a  new 
program with a start time of 23.01 and the 
same temperature as Ρ5.

9. 

Press the key         and the minutes digit 

starts to blink.

 

With the keys          and

12. Press the             key and the         symbol               
will  blink.  This  shows  that  you  are  in  the 
second program.

5.  Press  the  key                to  return  to  the 
previous screen with the           blinking.

15. Completing the daily program   you can 
store the programmed values to the devices 
memory by pressing 2 times the

       key  while the indication     is blinking.  
The screen will show               for awhile and 
then  normal  operation  will  continue.  By 
activating the device with the               key the 
daily  program  will  start  to  take  affect.  In 
order  for  the  program  to  execute  correctly 

select 00.

7. 

Press  the  key

     

 

   

  and  the  screen         

shows

        

 with

 

the 

    

 blinking

,  

this shows 

that  you  are  in  program  1  of  the  daily 
program 

(

the indication         indicates that 

the current program in empty

).

8. Press the key             and the hours digit 
starts to blink. With the keys          and

4. Press the key           and the           starts to 
blink. With the keys          and          select 
the  operation  mode          (Day  -  daily 
program).

6. 

Press the key       8 times and the screen 

shows         with the       blinking.

 

Now you 

are in the daily programming sub menu that 
has a 10 program capability.

10.  With  the  next  press  of  the          key                       

 

the screen shows the temperature blinking 
and by using the               and               keys you 
select  22,5°C.  This  concludes  the 
programming of the first program.

11. Press the                 key and the screen 
shows the symbol        blinking.

13. Follow the step 8, 9 and 10 and set the 
time to 8.30 (which is the end time of the first 
program) and the temperature to 21,5°C.

MENU

ENTER

MENU

ENTER

ESC

DAY

MENU

ENTER

MENU

ENTER

ESC

ESC

940851000_09_010

Summary of Contents for BS-850/KIT

Page 1: ...850 T BS 851 T BS 850 R BS 851 R Only for BS 851 R CONTROL AND INDICATIOR DESCRIPTION Thermostat inactive When the selection is less than the Presence indicator Thermostat activation Thermostat deactivation Increase value Thermostat active Decrease value Ascending or descending temperature indicator Battery state indicator actual temperature When the selection the differential is When the temperat...

Page 2: ...Selecting on not the area presence program Activate Deactivate boiler valid only for the BS 851 T Go to the next item or selection Select normal or night program Go to the previous item or selection Select and confirm installation settings Daily program activation indicator Weekly program activation indicator Night program activation indicator Burner activation indicator Power supply and programmi...

Page 3: ... the included card Otherwise you can insert the serial number by typing the 32digit on the included card 3 If you want to add a device to your home network firstly you have to connect your smartphone to the network which your thermostat will be connected CONTENTS CONTENTS Setting time date page 6 Thermostat operation mode page 7 Temperature indication unit page 7 Entering the MENU page 5 Setting u...

Page 4: ...ere is internet connection By finishing the process successfully you will be able to guide to the main screen of the app and your device will be visible furthermore you can control it The screen of the thermostat is refreshing every five minutes therefore the command from your smartphone might not be visible to the screen immediately but this does not mean that it is not executed Note 1 Through Ol...

Page 5: ...it has been preselected via the ΜΕΝU setting with the indication GENERAL When the plastic battery separator is removed the unit is automatically activated and shows all the screen indicators for 1 then the firmware version is shown and finally the screen enters final operation status In the center of the screen you can see the current temperature The clock has the hour 00 00 the date is 1 January ...

Page 6: ...EEKLY PROGRAM the thermostat is in the OFFstate If immediately after entering the ΜΕΝU press the key for 2 times the message 7days will be shown on the bottom of the screen and the word WEEK on the top right On the top left of the screen there is the message ΜΟ Monday that shows the day that corresponds to the programming that follows By pressing again the key the screen shows a blinking that dete...

Page 7: ...ion the symbol DAYis shown on the top right of the screen With this setting you can turn off the screen illumination in order to conserve battery energy If ΟΝ is selected then the screen illumination will be activated every time a key is pressed If is selected then the screen illumination will be deactivated With this setting you can determine the time period for which the manual temperature adjus...

Page 8: ... H Time HOUR METER The battery life time has been design to be approximately one year Factors that influence the battery life are prolong use of the keyboard with the backlight active increased temperature and humidity as well as battery quality Daily program selection Day Weekly program selection Week 13 CLEANING THE THERMOSTAT Time and date setting SetTime Operation mode selection Mode If the ro...

Page 9: ...7 00 at 19 8 C Keypad state Unlocked select 07 14 Following the steps 8 9 10 and 11 to adjust the remaining programs with the values 12 00 18 5 C 17 30 22 5 C and 23 00 19 8 C If by mistake you add a new program ex Ρ6 this program can t be canceled but can be defined as a new program with a start time of 23 01 and the same temperature as Ρ5 9 Press the key and the minutes digit starts to blink Wit...

Page 10: ...d press the key 6 Activate the device using the key The weekly program will start to execute as WEEKLYPROGRAMING EXAMPLE make sure you have programmed the device clock with the correct time the thermostat in the OFF state prolonged press of the MENU ENTER key and then 22 consecutive presses of the key lead us to the screen The number of dashes verifies the correct connection between the two device...

Page 11: ...e interruption of the mains voltage causes the interruption of communication between the two devices When the voltage is restored the peripheral device receiver activates the outputs according to the state before the interruption until the communication is automatically restored with the thermostat maximum delay of 6 minutes so the outputs will change according to the new commands that will be giv...

Page 12: ...ark and drill the mounting holes according to the schematic in page 11 Mount the device using the supplied mounting accessories Holes Aand B as shown in Fig 5 Do the electrical connections according to Fig 5 Connect the phase to the L terminal and the neutral to the N terminal this is used to power the device The phase cable for the outputs is to the common of the relay contacts In every activatio...

Page 13: ...ct the power supply before any interference with the system Make sure that the device is installed on the wall according with the installation instructions Connect the power cables according to the installation instructions Use only the products and accessories listed in the technical specifications for any system expansions Hereby Olympia Electronics N Lakasas P Arvanitidis S A declares that the ...

Page 14: ... buyer the transportation cost P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics com HEAD OFFICE info olympia electronics gr 72nd km O N R Thessaloniki Katerini TECHNICAL CHARACTERISTICS WARRANTY WARRANTY POWERED BY 2 Alkaline ΑΑ BS 850 T BS 851 T BS 850 R BS 851 R MODEL 220 240V AC 50 60Hz OPERATION TEMPERATURE RANGE SAMPLING PERIOD EMC TEST RELATIVE HUMIDITY EXTERNALDIMENSIONS T...

Reviews: