background image

Page

 

13 from

 

13

940851000

_09_001

Olympia Electronics guarantees the quality, condition and operation of the goods. The 
period of warranty is specified in the official catalogue of Olympia Electronics and also 
in the technical leaflet, which accompanies each product. This warranty ceases to 
exist  if  the  buyer  does  not  follow  the  technical  instructions  included  in  official 
documents given by Olympia Electronics or if the buyer modifies the goods provided 
or has any repairs or re-setting done by a third party, unless Olympia Electronics has 
fully agreed to them in writing. 

Products that have been damaged can be returned to 

the premises of our company for repair or replacement, as long as the warranty period 
is valid.

 Olympia Electronics reserves the right to repair or to replace the returned 

goods and to or not charge the buyer depending on the reason of defection. Olympia 
Electronics reserves the right to charge or not the buyer the transportation cost.

HEAD OFFICE

72nd km. O.N.R. Thessaloniki-Katerini

P.C. 60300 P.O. Box 06 Εginio Pierias Greece

www.olympia-electronics.gr
info@olympia-electronics.gr

TECHNICAL CHARACTERISTICS

POWERED BY

2

  

Alkaline

 ΑΑ

BS-850/T - BS-851/T

BS-850/R - BS-851/R

MODEL

220 - 240V AC / 50-60Hz

OPERATION TEMPERATURE RANGE

RELATIVE HUMIDITY

EXTERNAL DIMENSIONS

TYPICAL WEIGHT

GUARANTEE

MEASURING RANGE

OPEN RELAY CONTACT

DEGREES OF COVER PROTECTION

 

PRODUCED IN ACCORDANCE WITH

2x

5Α - 250

V AC1

o

0.0 

to

 99.9 

C

EN 61000-6-1, EN 61000-6-3, EN 60730-1, EN 60730-2-9

o

5 to 35  C

10 -

 90% RH 

2 years

121.5 x 27.3 x 81.3 mm

IP20

175 gr. (with batteries)

200

 

gr

.

o

-10 to 50  C

10 -

 9

5

% RH 

120 x 34 x 80 mm 

-

CONSUMPTION

1.9VA

WARRANTY

WARRANTY

-

COMMUNICATION FREQUENCY

869,75

MHz

TEMPERATURE SELECTION RANGE

o

6.0 

to

 30.0 

C

-

-

Summary of Contents for BS-850/R

Page 1: ...S 851 T BS 850 R BS 851 R Only for BS 851 R CONTROL AND INDICATIOR DESCRIPTION Thermostat activation Thermostat deactivation Increase value Decrease value Presence indicator Thermostat active Thermostat inactive Battery state indicator Ascending or descending temperature indicator When the selection is less than the actual temperature When the selection the differential is more than the actual tem...

Page 2: ...or selection Select normal or night program Go to the previous item or selection Select and confirm installation settings Daily program activation indicator Weekly program activation indicator Manual program activation indicator Day of the week indicator Night program activation indicator Burner activation indicator Boiler activation indicator valid only for the BS 851 R Normal program activation ...

Page 3: ... serial number located inside the receiver or scan the QR Code on the included card Otherwise you can insert the serial number by typing the 32digit on the included card Figure 2 Figure 3 2 Figure 4 CONTENTS CONTENTS Setting up the device page 3 Entering the MENU page 5 Day or Night operation page 5 Boiler activation selection page 5 Presence selection page 5 Keypad lock page 6 Setting time date p...

Page 4: ...n Figure 1 on the thermostat and at the end the SEND icon from the application Figure 7 When they connect the LD4 must blink every 2 seconds while the LD5 must be off which means there is internet connection By finishing the process successfully you will be able to guide to the main screen of the app and your device will be visible furthermore you can control it The screen of the thermostat is ref...

Page 5: ...f the program that was running before absence mode was selected GENERAL When the plastic battery separator is removed the unit is automatically activated and shows all the screen indicators for 1 then the firmware version is shown and finally the screen enters final operation status In the center of the screen you can see the current temperature The clock has the hour 00 00 the date is 1 January F...

Page 6: ... consecutive presses of the key you can select the remaining programs of the 24 hour cycle 10 in total and can set the required time periods and temperatures as described above Please note that for every program define only the start time since the end time is the start time of the next program For example if you desire a temperature of 23 0º C from 14 00 to18 00 in program 1 set the start time 14...

Page 7: ...the top right of the screen The factory default is Β Unit TEMPERATURE UNIT The option are or Degree Celsius ή Degree Fahrenheit and regard the display of the temperature in ºC or ºF Depending on the selection the symbol ºC or ºF are shown on the center right of the screen C B a c k L i g h t S C R E E N ILLUMINATION With this setting you can turn off the screen illumination in order to conserve ba...

Page 8: ...ut it will not permit it to operate The battery life time has been design to be approximately one year Factors that influence the battery life are prolong use of the keyboard with the backlight active increased temperature and humidity as well as battery quality 12 ANTI ICE PROTECTION If the room temperature in which the thermostat is installed falls below 5 C the unit activates the burner output ...

Page 9: ... screen shows with the Mode blinking 4 Press the key and the starts to blink With the keys and select the operation mode Day daily program 5 Press the key to return to the previous screen with the blinking 6 Press the key 8 times and the screen shows with the blinking Now you are in the daily programming sub menu that has a 10 program capability 7 Press the key and the screen shows with the blinki...

Page 10: ...is blinking The screen will show the message briefly and the settings will be stored in to the devices memory 6 Activate the device using the key The weekly program will start to execute as defined In order for the program to execute correctly make sure you have programmed the device clock with the correct time WIRELESS CONNECTION SETTING After installing the peripheral received BS 851 R press the...

Page 11: ...een will blink The interruption of the mains voltage causes the interruption of communication between the two devices When the voltage is restored the peripheral device receiver activates the outputs according to the state before the interruption until the communication is automatically restored with the thermostat maximum delay of 6 minutes so the outputs will change according to the new commands...

Page 12: ... is ready to operate Fig 4 To install the BS 851 R remove the front cover with a screwdriver Fig 4 Mark and drill the mounting holes according to the schematic in page 11 Mount the device using the supplied mounting accessories Holes Aand B as shown in Fig 5 Do the electrical connections according to Fig 5 Connect the phase to the L terminal and the neutral to the N terminal this is used to power ...

Page 13: ...o repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R Thessaloniki Katerini P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics gr info olympia electronics gr TECHNICAL CHARACTERISTICS POWERED BY 2 Alkaline ΑΑ BS ...

Reviews: