SELECTING THE UPPER AND LOWER 

L I M I T S   O F   T H E   M A N U A L  
TEMPERATURE  ADJUSTMENT

 

(

the 

thermostat is in the OFF state)

.

After  entering  the 

  and  by 

MENU

consecutive  presses  of  the  key         

 

the 

message             

   

(High Temperature Limit)   

will

 

be shown on the bottom of the screen

           

 

as  well  as  the  initial  value

  30.0  º

C

By 

pressing the key             you can change this 
temperature  between  the  lower     

   

limit             

and the value of 

30.0 º

C. By pressing the 

key       

  

and then immediately the      

   

key       

the lower section of the screen shows the 
message         

 

 (Low Temperature Limit)

 

as 

well as the initial temperature

 

of 

6.0 

ºC.

 

With 

the           

 

key  you  can  adjust  the  value 

between  

6.0 

ºC

 

and the value of the upper 

limit

The  two  limits  define  a  temperature 

area that can be used by the user to enter 
the  desired  temperature.

 

The  selection  of 

the limits influences the manual adjustment 
of the temperature and is independent from 
the  operating  mode  of  the  unit

  (

manual, 

daily  weekly

and  does  not  have  any 

influence  on  the  programs  for  daily  or 
weekly operation

.

10.OTHER  MENU  SETTINGS 

(

the 

thermostat is in the OFF state)

.

All  the  menu  settings  that  follow  can  be 
changed  by  using  the  same  method  as 
described  in  the  previous  chapters.  After 
entering  the 

  use  the           

 

key  to 

ΜΕΝU

select the required setting.

  

The messages 

are  shown  in  the  bottom  section  of  the 
screen like this:

A.          (Mode) OPERATION MODE

.

One  of  three  operation  modes  can  be 
selected:      
                 (User

Manual mode

 (

the symbol 

ΜΑΝ

.   

is  shown  on  the  top  right  of  the 

screen

).

               (Day) daily operation   (the symbol   

DAY 

is shown on the top right of the screen.

          (7 Days) weekly program (the symbol 

WΕΕK

  is  shown  on  the  top  right  of  the 

screen).

The factory default is         .

Β.    

          (Unit) TEMPERATURE UNIT

.

The option are:                 or               (Degree 
Celsius  ή  Degree  Fahrenheit)  and  regard 
the display of the temperature in ºC or ºF. 
Depending on the selection, the symbol ºC 
or ºF are shown on the center right of the 
screen.

C

.       (

B a c k   L i g h t )   S C R E E N  

ILLUMINATION.

With this setting you can turn off the screen 
illumination  in  order  to  conserve  battery 
energy

.

  If 

 

     

(ΟΝ)

  is  selected  then  the 

screen illumination will be activated every 
time a key is pressed. If               is selected 
then  the  screen  illumination  will  be 
deactivated
The factory default is       .

D

.

       

(

LED)  BURNER  OUTPUT 

INDICATOR

.

This  setting  can  deactivate  the  burner 
output indicator in order to conserve battery 
energy.

If           (ON) is selected then when 

the burner output is active the indicator will 
briefly blink every second so the user has a 
knowledge  of  the  state  of  the  thermostat 
from a distance.

If         (OFF) is selected 

then the indicator is deactivated.

Ε.       

   

   (

Time Out) TEMPORARY TIME 

FOR MANUAL OPERATION.

With this setting you can determine the time 
period  for  which  the  manual  temperature 
adjustment is valid. When the thermostat is 
running a daily or weekly program and you 
press the keys               or             , either you 
change  the  temperature  through  the 
application,  then  the  thermostat  enters 
briefly the manual mode for a time period 
that is determined by the setting          . The 
value  of  this  setting  can  be  from  3  to  10 
hours  after  which  normal  program 
execution is continued.

  

The factory default 

is 3 hours.

F

.            (

Differential)  DIFFERENTIAL 

SETTING

.

This setting determines the 

 temperature 

w i n d o w

 

b e t w e e n   a c t i v a t i o n   a n d  

deactivation  of  the  burner  output.

 

For 

example, if the room temperature is set to 

23.0 °

C then with a differential of 

0.5 °

C

 

the 

output to the burner will be deactivated at 

23.0 °

C and will be reactivated at 

22.5 °

C.

MENU

ENTER

ESC

MENU

ENTER

Summary of Contents for BS-850/R

Page 1: ...S 851 T BS 850 R BS 851 R Only for BS 851 R CONTROL AND INDICATIOR DESCRIPTION Thermostat activation Thermostat deactivation Increase value Decrease value Presence indicator Thermostat active Thermostat inactive Battery state indicator Ascending or descending temperature indicator When the selection is less than the actual temperature When the selection the differential is more than the actual tem...

Page 2: ...or selection Select normal or night program Go to the previous item or selection Select and confirm installation settings Daily program activation indicator Weekly program activation indicator Manual program activation indicator Day of the week indicator Night program activation indicator Burner activation indicator Boiler activation indicator valid only for the BS 851 R Normal program activation ...

Page 3: ... serial number located inside the receiver or scan the QR Code on the included card Otherwise you can insert the serial number by typing the 32digit on the included card Figure 2 Figure 3 2 Figure 4 CONTENTS CONTENTS Setting up the device page 3 Entering the MENU page 5 Day or Night operation page 5 Boiler activation selection page 5 Presence selection page 5 Keypad lock page 6 Setting time date p...

Page 4: ...n Figure 1 on the thermostat and at the end the SEND icon from the application Figure 7 When they connect the LD4 must blink every 2 seconds while the LD5 must be off which means there is internet connection By finishing the process successfully you will be able to guide to the main screen of the app and your device will be visible furthermore you can control it The screen of the thermostat is ref...

Page 5: ...f the program that was running before absence mode was selected GENERAL When the plastic battery separator is removed the unit is automatically activated and shows all the screen indicators for 1 then the firmware version is shown and finally the screen enters final operation status In the center of the screen you can see the current temperature The clock has the hour 00 00 the date is 1 January F...

Page 6: ... consecutive presses of the key you can select the remaining programs of the 24 hour cycle 10 in total and can set the required time periods and temperatures as described above Please note that for every program define only the start time since the end time is the start time of the next program For example if you desire a temperature of 23 0º C from 14 00 to18 00 in program 1 set the start time 14...

Page 7: ...the top right of the screen The factory default is Β Unit TEMPERATURE UNIT The option are or Degree Celsius ή Degree Fahrenheit and regard the display of the temperature in ºC or ºF Depending on the selection the symbol ºC or ºF are shown on the center right of the screen C B a c k L i g h t S C R E E N ILLUMINATION With this setting you can turn off the screen illumination in order to conserve ba...

Page 8: ...ut it will not permit it to operate The battery life time has been design to be approximately one year Factors that influence the battery life are prolong use of the keyboard with the backlight active increased temperature and humidity as well as battery quality 12 ANTI ICE PROTECTION If the room temperature in which the thermostat is installed falls below 5 C the unit activates the burner output ...

Page 9: ... screen shows with the Mode blinking 4 Press the key and the starts to blink With the keys and select the operation mode Day daily program 5 Press the key to return to the previous screen with the blinking 6 Press the key 8 times and the screen shows with the blinking Now you are in the daily programming sub menu that has a 10 program capability 7 Press the key and the screen shows with the blinki...

Page 10: ...is blinking The screen will show the message briefly and the settings will be stored in to the devices memory 6 Activate the device using the key The weekly program will start to execute as defined In order for the program to execute correctly make sure you have programmed the device clock with the correct time WIRELESS CONNECTION SETTING After installing the peripheral received BS 851 R press the...

Page 11: ...een will blink The interruption of the mains voltage causes the interruption of communication between the two devices When the voltage is restored the peripheral device receiver activates the outputs according to the state before the interruption until the communication is automatically restored with the thermostat maximum delay of 6 minutes so the outputs will change according to the new commands...

Page 12: ... is ready to operate Fig 4 To install the BS 851 R remove the front cover with a screwdriver Fig 4 Mark and drill the mounting holes according to the schematic in page 11 Mount the device using the supplied mounting accessories Holes Aand B as shown in Fig 5 Do the electrical connections according to Fig 5 Connect the phase to the L terminal and the neutral to the N terminal this is used to power ...

Page 13: ...o repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R Thessaloniki Katerini P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics gr info olympia electronics gr TECHNICAL CHARACTERISTICS POWERED BY 2 Alkaline ΑΑ BS ...

Reviews: