background image

24

25

26

27

28

15

14

13

12

11

1

0

16

17

18

19

20

21

22

23

2

9

30

ESC

MENU

ENTER

1

2

3

4

5

20

19

18

17

16

15

21

23

24

26

27

28

25

22

7

8

9

10

12

14

11

6

13

 

 

31

BOILER

 

29

30

POWER

OPERATION

BURNER

31

Hour and message display

  

Temperature and message display
Temperature units display
Active burner output display
Selecting on not the area presence program
Escape from a selection
Activate / Deactivate boiler 

(valid only for the BS-851/T)

Go to the next item or selection
Select normal or night program
Go to the previous item or selection
Select and confirm installation settings
Daily program activation indicator
Weekly program activation indicator
Manual program activation indicator
Day of the week indicator
Night program activation indicator
Burner activation indicator
Boiler activation indicator 

(valid only for the BS-851/R)

Normal program activation indicator

Power supply and programming status indicator

Burner activation indicator

Boiler activation indicator 

(valid only for the BS-851/R)

Wi

WPS

Button

Manual

Button

LD5

LD

1

LD

4

Programming

Key

Serial

Number

Figure 1

Page

 

2 from

 

13

940851000

_09_001

Summary of Contents for BS-850/T

Page 1: ...851 T BS 850 R BS 851 R Only for BS 851 R CONTROL AND INDICATIOR DESCRIPTION Thermostat activation Thermostat deactivation Increase value Decrease value Presence indicator Thermostat active Thermostat...

Page 2: ...r selection Select normal or night program Go to the previous item or selection Select and confirm installation settings Daily program activation indicator Weekly program activation indicator Manual p...

Page 3: ...serial number located inside the receiver or scan the QR Code on the included card Otherwise you can insert the serial number by typing the 32digit on the included card Figure 2 Figure 3 2 Figure 4 CO...

Page 4: ...Figure 1 on the thermostat and at the end the SEND icon from the application Figure 7 When they connect the LD4 must blink every 2 seconds while the LD5 must be off which means there is internet conn...

Page 5: ...of the program that was running before absence mode was selected GENERAL When the plastic battery separator is removed the unit is automatically activated and shows all the screen indicators for 1 the...

Page 6: ...With consecutive presses of the key you can select the remaining programs of the 24 hour cycle 10 in total and can set the required time periods and temperatures as described above Please note that fo...

Page 7: ...he top right of the screen The factory default is Unit TEMPERATURE UNIT The option are or Degree Celsius Degree Fahrenheit and regard the display of the temperature in C or F Depending on the selectio...

Page 8: ...t it will not permit it to operate The battery life time has been design to be approximately one year Factors that influence the battery life are prolong use of the keyboard with the backlight active...

Page 9: ...screen shows with the Mode blinking 4 Press the key and the starts to blink With the keys and select the operation mode Day daily program 5 Press the key to return to the previous screen with the bli...

Page 10: ...blinking The screen will show the message briefly and the settings will be stored in to the devices memory 6 Activate the device using the key The weekly program will start to execute as defined In or...

Page 11: ...en will blink The interruption of the mains voltage causes the interruption of communication between the two devices When the voltage is restored the peripheral device receiver activates the outputs a...

Page 12: ...is ready to operate Fig 4 To install the BS 851 R remove the front cover with a screwdriver Fig 4 Mark and drill the mounting holes according to the schematic in page 11 Mount the device using the sup...

Page 13: ...to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost...