Page
7 from
13
940851000
_09_001
for all the 24 hour base
.
9
.
SELECTING THE UPPER AND LOWER
L I M I T S O F T H E M A N U A L
TEMPERATURE ADJUSTMENT
(
the
thermostat is in the OFF state)
.
After entering the
and by
MENU
consecutive presses of the key
the
message
(High Temperature Limit)
will
be shown on the bottom of the screen
as well as the initial value
30.0 º
C
.
By
pressing the key you can change this
temperature between the lower
limit
and the value of
30.0 º
C. By pressing the
key
and then immediately the
key
the lower section of the screen shows the
message
(Low Temperature Limit)
as
well as the initial temperature
of
6.0
ºC.
With
the
key you can adjust the value
between
6.0
ºC
and the value of the upper
limit
.
The two limits define a temperature
area that can be used by the user to enter
the desired temperature.
The selection of
the limits influences the manual adjustment
of the temperature and is independent from
the operating mode of the unit
(
manual,
daily weekly
)
and does not have any
influence on the programs for daily or
weekly operation
.
10.OTHER MENU SETTINGS
(
the
thermostat is in the OFF state)
.
All the menu settings that follow can be
changed by using the same method as
described in the previous chapters. After
entering the
use the
key to
ΜΕΝU
select the required setting.
The messages
are shown in the bottom section of the
screen like this:
A. (Mode) OPERATION MODE
.
One of three operation modes can be
selected:
(User
)
Manual mode
(
the symbol
ΜΑΝ
.
is shown on the top right of the
screen
).
(Day) daily operation (the symbol
DAY
is shown on the top right of the screen.
(7 Days) weekly program (the symbol
WΕΕK
is shown on the top right of the
screen).
The factory default is .
Β.
(Unit) TEMPERATURE UNIT
.
The option are: or (Degree
Celsius ή Degree Fahrenheit) and regard
the display of the temperature in ºC or ºF.
Depending on the selection, the symbol ºC
or ºF are shown on the center right of the
screen.
C
. (
B a c k L i g h t ) S C R E E N
ILLUMINATION.
With this setting you can turn off the screen
illumination in order to conserve battery
energy
.
If
(ΟΝ)
is selected then the
screen illumination will be activated every
time a key is pressed. If is selected
then the screen illumination will be
deactivated
The factory default is .
D
.
(
LED) BURNER OUTPUT
INDICATOR
.
This setting can deactivate the burner
output indicator in order to conserve battery
energy.
.
If (ON) is selected then when
the burner output is active the indicator will
briefly blink every second so the user has a
knowledge of the state of the thermostat
from a distance.
.
If (OFF) is selected
then the indicator is deactivated.
Ε.
(
Time Out) TEMPORARY TIME
FOR MANUAL OPERATION.
With this setting you can determine the time
period for which the manual temperature
adjustment is valid. When the thermostat is
running a daily or weekly program and you
press the keys or , either you
change the temperature through the
application, then the thermostat enters
briefly the manual mode for a time period
that is determined by the setting . The
value of this setting can be from 3 to 10
hours after which normal program
execution is continued.
The factory default
is 3 hours.
F
. (
Differential) DIFFERENTIAL
SETTING
.
This setting determines the
”
temperature
w i n d o w
”
b e t w e e n a c t i v a t i o n a n d
deactivation of the burner output.
For
example, if the room temperature is set to
23.0 °
C then with a differential of
0.5 °
C
the
output to the burner will be deactivated at
23.0 °
C and will be reactivated at
22.5 °
C.
MENU
ENTER
ESC
MENU
ENTER