TECHNICAL CHARACTERISTICS

Operation temperature range

Produced in accordance with

Humidity
Dimensions
Weight
Guarantee

Operation Voltage

Description

Outputs
Contacts
Indicators 
Temperature adjustment 
Differential
Degrees of cover protection

220 - 240V AC / 50 - 60Hz

Contact 8Α (for resistive load) 

ON - OFF

Output activation indicator

ο

5 to 35 C

o

1 C

IP 20

ο

Up to 50  C

Up to 65% relative humidity

86x83x35mm

120gr.

2 years

 Room thermostat

EN 60730

980190000_09_007

Page 1 of

 

3

BS-90

0

                         Room thermostat

Thank you for your trust in our products  

Olympia Electronics -  European manufacturer

GENERAL

The room thermostat is used in areas where it is 
essential to control the temperature. The contact 
of  the  thermostat  can  activate  any  heating 
device.
The  thermostat  is  mounted  at  a  height  of  about 
1,5  meters  and  away  from  doors,  drafts  and 
heating or cooling units.
When the switch of the  thermostat is in the OFF 
position then the thermostat does not operate. In 
the  ON  position,  the  thermostat  is  fully 
operational. 
The  adjustment  of  the  thermostat  must  be  done 
30  minutes  after  powering  the  unit.  This  time  is 
required in order for the thermostat to adjust to its 
surroundings.

Connections

1.  Rotate  the  adjustment  knob  to  the  maximum 

ο

position (35 C).Place a flat blade screwdriver in the 
notch between the base and the knob and lift until 
the knobs comes freely. 
2. To separate the cover from the base, unfasten 
the retaining screw and press the   plastic hooks, 
found on the top and bottom side and pull the cover 
with extra care.

After  removing  the  cover  we  can  see  4  terminal 
blocks that are numbered and shown in page 1. 
First we connect the burner with the neutral of the 

mains  power  supply  and  with  terminal  3  of  the 
thermostat. Connect terminal 1 of the thermostat 
with the mains phase wire and terminal 4 with the 
mains neutral wire. 
3. 

Place  vertically  and  with  extra  care  the 

plastic  cover  in  order  not  to  destroy  the 
indication  lamp 

and  after  the  plastic  hooks  are 

locked, fasten the removed screw in step 2, refit the 

adjustment  knob  and

  the  thermostat  is  ready  to 

operate.

Scale adjustment (if necessary).

The  thermostat  has  been  pre-adjusted  at  the 
factory.  If  for  any  reason,  the  scale  of  the 
thermostat  does  not  correspond  the    actual 
temperature  then  it  can  be  adjusted.  This 
procedure  must  be  done  at  least  48  hours  after 
installing  the  thermostat. To  adjust  the  scale  first 
measure the temperature near the thermostat with 
another  thermometer.  Subtract  this  temperature 
with the indicated temperature on the scale of the 
thermostat.  (e.i. If the measured temperature is 23 
degrees and the scale reads 25 degrees then we 
have 25-23 = 2 degrees difference). Remove the 
adjustment  knob.  This  knob  consists  of  two 
sections. The external section(Fig.2) with the  anti-
slipping area and the internal area (Fig.3) with the 
scale On the back side of the knob we can see a 
scale  with  lines.  Each  line  corresponds  to  1 