4
The light source contained in this luminaire shall only be replaced by the
manufacturer, or his agent, or a similar qualified person.
NOTE! The light source is non-user replaceable.
INSTALLATION INSTRUCTIONS
3
2
Initial installation
1
Untighten the screw and pull up the reflector.
2
Always use in any case round mains cable
,
with a diameter
of 5
-
10mm (H05RN-F type 2x1mm²
or
any
other type
,
at least
equal
to it’s mechanical and electrical properties). ATTENTION!!
The cable must not be deformed in any way (This requirement is important to ensure the
ΙΡ
rating).
Install
the included gaskets in to the cable entry holes
(verify that are not deformed)
. Make a
hole in the center by using a small screwdriver. Pass the round cable through the gasket. Detach the
power terminal, connect the wires as shown in the picture and attach the power terminal
(10A max)
.
3
Place the battery’s connector to the corresponding connector on the P.C.B.
4
Refit the reflector (mind the correct orientation), tighten the screw securely and the luminaire
is ready for mounting
.
NOTE!! After finishing the installation you must power the luminaire for, at least, 24 hours for
battery charging to perform the nominal autonomy.
GR-27
0
, GR-272
GR-271, GR-273
ATTENTION!!!
During installation follow this light direction.
Corridor
lighting
Open
area
lighting
CHARGE
TEST
CHARGE
TEST
CHARGE
TEST
9
6
6
5
125
CHARGE
TEST
Battery
charge
indication
LED
Figure 4
Test
button
923270000_09_00
4
L
N
Cable
entry
hole
1