stated in the list of the first page. During
emergency mode, a LED strip test is also
performed.
Resetting Errors
Push the Test button for 5 seconds, to
extinguish all the indicated LED errors. Then
the luminaire enters regular operation mode.
Indication LED status (with connected
mains power supply).
Charge
On:
Good charge current.
Οff:
No battery (No charging current or
disconnected battery).
Lamp Fault
Οn:
Faulty LED strip.
Off:
Good LED strip.
Battery Fault
Οff:
Battery OK.
Blink
(With
Charge LED
ON): Autonomy or
low battery problem
(the battery must be replaced).
Blink
(With
Charge LED
Off):
No charging current or disconnected battery.
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance or
testing must be done by authorized personel
only.
2. The device must be connected to the mains
power supply thru a fuse dependent by the
total amount of the line’s power load.
In case of battery or light source replacement,
these must be replaced by parts of the same
type, by the manufacturer or by a competent
person.
t i
in battery recycling
points. Do not incinerate.
3.
4. In case of inactive use for a period greater
than 2 months, disconnect the battery by
pulling out the battery’s connector.
5.
I s not allowed to discard batteries in to
common trash bins, they must be
discarded only
Suspended ceiling
Α-3018 mounting springs
1
2
3
Mounting methods
All luminaires, can be mounted either surface or in
suspended ceilings.
Suspended ceiling installation.
On the bottom of the base plastic of the luminaire
there are two
H
shaped cut outs. These are used to
install the A-3018 mounting springs.
1. With a sharp tool remove the appropriate plastic
pieces to fit the mounting springs. First place the
edges of the mounting spring to the respective holes
and install the one end of the coil to the support axis.
2. Install the other end of the coil to the other support
axis.
3. Bend the springs and place the luminaire to the
respective suspended ceiling’s hole.
The luminaire’s placement to the suspended ceiling
must be done after the connection with power supply
cables.
Mounting the luminaire
in a suspended ceiling
Required
opening in
a suspended
ceiling
260
110
923423012_09_002