GENERAL

o

These  luminaires  are  used  indoors 

(

ta  40 C

)

 

where emergency light is needed.
E a c h   l u m i n a i r e   m u s t   b e   p e r m a n e n t l y  
connected to mains power supply

.

In normal operation  the led strip lights and the 
battery is charging.
In  case  of  a  mains  power  supply failure  the  
luminaire  will  light the led strip  automatically 
in emergency mode.  When the  mains  power  
supply    is    restored  the  device  turns  to  normal 
operation.
 

INSTALLATION

To  install  the  luminaire  follow  the  installation 
instructions on page 4.

Battery Cut-off

The luminaire enters in this operation when the 
mains  power  supply  fails

 

and  battery  has  lost 

its  energy

During  this  operation  the  luminaire 

enters the idle state

 

and battery consumption is 

negligible,  in  order  to  be  protected  from  deep 
discharge.

Battery charging

The battery charging is completely controled

In 

this  case,  is

 

achieved  the  perfect    battery 

maintenance 

as  well  as  the  elongation  of  its 

duration

When  the  battery  has  completely 

charged

it  charges  with  a  maintenance 

current.

Manual

 Test

The  manual  test  can  be  conducted  only  if  the 
main power supply and the battery is connected. 
By  pressing  the  test  button  briefly  an  operation 
test  is  initiated.  During  this  test  period  all 
indication LEDs are OFF.

Automatic test

This test includes all the operations that provide 
the  manual  test  and  is  conducted  automatically 
every  15  days.  In  order  to  be  performed,  the 
main  power  supply  and  the  battery  should  be 
connected. 

Automatic Autonomous Test

The  Automatic  autonomous  Test  is  conducted 
and  measures  the  luminaire`s  back  up 
operation.  This  test  is  conducted  automatically 
every six months

In order to be performed, the 

main  power  supply  and  the  battery  should  be 
connected  (the  battery  should  be  charged)

If 

the battery is not charged

the test is postponed

 

until the battery is  completely charged. If during 
the  Automatic  Autonomous  Test  the  luminaire’s 
duration  is  lower  than  the  named,  then  the 
battery must be replaced. 

Back Up Operation

The  autonomous  duration  of  battery  during 

923427000_09_00

5

Page

 1

 from

 5

GR-427/12L SELF TESTING MAINTAINED EMERGENCY LUMINAIRE

220-240V AC/50-60Hz

Bayblend FR3010

transparent 

 

polycarbonate

TECHNICAL CHARACTERISTICS

 

(for LED MODULE Specs. see page 

5

)

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

EXTERNAL DIMENSIONS 

CONSTRUCTION MATERIALS 

TYPICAL WEIGHT

GUARANTEE 

OPERATION VOLTAGE

MAXIMUM POWER CONSUMPTION
BATTERY

 (

Ni-Cd

)

CHARGING TIME

INDICATIONS 

CONTROLS

BATTERY PROTECTION

MINIMUM AUTONOMOUS DURATION

DEGREES OF COVER PROTECTION

PRODUCED IN ACCORDANCE WITH

ILLUMINATION (230V / EMERGENCY)

ILLUMINATION SOURCE 

480 min

24h

Charge, lamp fault, fault indication LED

TEST button

From overcharge and full discharge

IP42

  12 white LED’s 

EN 60598-1, EN 60598-2-22

, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3

5 to 40  C

o

Up to 95% 

3 years 

(1 

year for the battery

)

272 

x 121 x 50 mm

600gr.

  100lm / 100lm 

3,6

V/3Ah

3,5

W / 7VA

Thank you for your trust in our products  

Olympia Electronics -  European manufacturer

Summary of Contents for GR-427/12L

Page 1: ...rformed the main power supply and the battery should be connected Automatic Autonomous Test The Automatic autonomous Test is conducted and measures the luminaire s back up operation This test is conducted automatically every six months In order to be performed the main power supply and the battery should be connected the battery should be charged If the battery is not charged the test is postponed...

Page 2: ...type by the manufacturer or by a competent person t i in battery recycling points Do not incinerate 3 4 In case of inactive use for a period greater than 2 months disconnect the battery by pulling out the battery s connector 5 I s not allowed to discard batteries in to common trash bins they must be discarded only Suspended ceiling Α 3018 mounting springs 1 2 3 Mounting methods All luminaires can ...

Page 3: ...ire as shown in the pictures below The panel is pre printed and has a plastic accessory on each side that is used to fasten the panel to the luminaires There are 2 arrow stickers that can be placed in each side of the marking panel to point to the desired direction Placing the SP 115 marking panel Place the plastic mounting accessories of the marking panel as shown in pictures A 3018 SP 115 markin...

Page 4: ...ained operation The L1 wire can be connected to an external switch to control the maintained or non maintained operation of the luminaire For permanent maintained operation use two wires to power the luminaire Ν for neutral and L for live wire and link the L and L1 7 Refit the removed parts in steps 2 and 3 mind the correct orientation and the luminaire is ready to operate N N L L External switch ...

Page 5: ...ge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R Thessaloniki Katerini P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics gr info olympia electronics gr LED MODULE CHARACTERISTICS Olympia Electronics S A 45 C max across the board 8 4 9 9VDC 2 16W 0211163 GR 427 12L Cable connection between main pcb and led module Manufacturer Model Number Voltage Range Connecti...

Reviews: