Back Up Operation
The autonomous duration of battery during
emergency mode is at least the one that is
stated
in
the
list
of
the
technical
characteristics. During emergency mode, a
light source test is also performed.
Resetting Errors
Place the test card A-1900 on the side of the
indications (page 4) and remove it after the
reset is conducted (the indications light in
sequence), to delete all the indicated LED
errors. Then the luminaire enters regular
operation mode.
Indication LED status (with connected
mains power supply).
Charge
On:
Good charge current.
Οff:
No battery
(
No charging current
or disconnected battery
).
Lamp Fault
(with L1 connected to L)
Οn
(with LED strip off)
:
Faulty LED strip
(must be replaced).
Οn
(with LED strip on)
:
Problem in the back
up circuit of the LED strip (must be checked
by an authorized personnel).
Off:
Good LED strip.
Battery Fault
Ο
ff
:
Battery OK.
Blink
(
With Charge LED ON):
Autonomy or
low battery problem
(the battery must be
replaced).
Blink
(
With Charge LED Off):
No charging
current or disconnected battery
.
ΑΤΤΕΝΤΙΟΝ!
!!
1. Operations for installation, maintainance
or testing must be done by authorized
personnel only, after a mains interruption
.
2. The device must be connected to the
m a i n s p o w e r s u p p l y t h r
o
u
g h
a f u s e
dependent on the total amount of the line’s
power load.
3.
In case of battery or lamp replacement,
these must be replaced by parts of the same
type, by the manufacturer or by a competent
person.
4. In case of inactive use for a period greater
than 2 months, disconnect the battery by
pulling out the battery’s connector.
5
.
I
s not allowed to discard batteries
t i
into common trash bins, they must
b e d i s c a r d e d o n l y
i n b a t t e r y
recycling points. Do not incinerate.
INSTALLATION
To install the luminaire follow the installation
instructions on page 3.
923
577
00
7
_09_0
01
The light source contained in this luminaire shall only be replaced by the manufacturer, or his
agent, or a similar qualified person.
NOTE! The light source is non-user replaceable.
(*)
Maintained operation:
The luminaire lights its illumination source, when it is powered by the
mains power supply or not
.
Non Maintained operation: The luminaire lights its illumination source, only in power supply’s
failure.
NOTE:
LED= Light Emitting Diode
LABELING EXPLANATION:
X:
Self contained
1:
Maintained (*)
A:
Including test device
G:
Internally illuminated
90:
1.5 hour duration
18
0:
3
hour duration