background image

923

060000

_23_01

3

Page

 

2 from

 

2

When  the  unit  is  removed  from  its  base,  the 
charging stops and the unit automatically enters the 
backup  operation.  Observe  that  the  illumination  is 
automatically  increased  to  the  maximum  level.  To 
decrease  the  light  level,  press  the  push  button 
continuously  until  the  desired  level  has  been 
reached.  By  decreasing  the  light  level,  the 
autonomous duration is increased.
Each  time  the  unit  enters  backup  operation,  the 
illumination level is automatically set to maximum.

 

If the unit is in backup operation for a time period 
that exceeds the above mentioned times, then the 
LEDs  will  go  OFF  in  order  to  protect  the  battery 
from  deep  discharge.  In  this  state  the  unit  is 
completely  inoperative  and  a  complete  24  hour 
charge is required  until its next use.

Photo-sensor activation - deactivation

 

By  default  the  photo-sensor  is  deactivated.  This 
means that the unit will light if it is in the ON state.

 

If  the  photo-sensor  is  activated  then  the  unit  will 
light only in the dark and if it is in the ON state. To 
activate  or  to  deactivate  the  photo-sensor  follow 
the same procedure as mentioned below:
Remove  the  unit  from  the  charging  base.  Press 
the  push  button  so  the  white  LEDs  turned  OFF. 
Release  the  button  and  press  again  continuously. 
In 2 seconds the LEDs will light. Continue pressing 
the push button for 6 more seconds until the LEDs 
blink briefly.
If the photo-sensor function was disabled then with 
this  procedure  it  will  be  enabled.  The  same 
procedure  is  used  to  disable  the  photo-sensor 
function.

Mounting on the wall

There are two notches on the charging base which 
are used to pass the mounting screws (figure 2).

Attention

- The luminaire is suitable for indoor use.
-  When  placing  the  unit  on  the  charging  base, 
ensure that the charging LED lights.
-  If  the  unit  is  not  used  for  long  periods  of  time, 
leave it on the charging base in order to keep the 
batteries charged.
- Do  not mount  the unit  at a distance  of less  than 
50  cm  from  a  wall  corner  in  order  to  avoid  photo-
sensor disturbances.
- When placing the unit on the charging base, align 
the  pins  of  the  unit  to  the  respective  pins  on  the 
base and press gently. Do not exert excess force. 

Replaced  batteries  must  not  be  thrown  into 

trash  bins.  They  must  be  returned  to 
special  battery  disposal  points.  Do  not 
incinerate.

- When the mains cable is damaged, this must be 
replaced  by  our  SERVICE  department  or  by  an 
authorized technician.

NOTE!!
After finishing the installation you must power 
the  luminaire  at  least  for  24  hours  for  battery 
charging to perform the named autonomy.

If  the  autonomous  duration  time  is  considerably 
less  than  nominal,  the  battery  must  be  replaced 
with a new one with the same type.

Battery replacement procedure 

(

figure

 3).

1. Detach the luminaire from its base figure 1.
2.  Unfasten  the  2  mounting  screws  of  the  rear 
plastic and remove it.
3. Remove the battery an place a new one with the 
same type and connect it as shown in the picture.
4.  Refit  the  rear  plastic  and  fasten  the  removed 
screws in step 1.

50 cm
minimum
distance

Used for wall
mounting

figure

 2

figure

 3

2

2

3

Charging 
contacts

Charging
indicator

Push
button

figure

 1

Reviews: