background image

o

These  luminaires  are  used  indoors 

(

ta  40 C

)

  on  the  wall,  where 

emergency  light  is  needed.  Each  luminaire  must  be  permanently 
connected  to  the  mains  power  supply

.

  In  normal  operation  the 

illumination LEDs are lit as well as the green indicating charge LEDs, 
when the battery is charging. In case of a mains power supply failure the 
luminaire    will  light  the  led  strip  automatically  in  emergency  mode. 
When the mains power supply is restored the device turns to normal 
operation.

Non-Maintained / Maintained operation 

there is an option to select 

the non maintained or maintained operation by placing the jumper to 
the appropriate place according to the Figure 4 (see page 2)

.

INSTALLATION

To install the luminaire follow the installation instructions

 

on page

 

2.

ΑΤΤΕΝΤΙΟΝ

!!!

1. Operations for installation, maintainance or testing must be done 

by authorized personnel only

.

2.

The  device  must  be  connected  to  the  mains  power  supply 

through  a  fuse  dependent  by  the  total  amount  of  the  line’s   
power load

.

3. It  is  suggested  to  check  every  month  the  indication  LED  for 

battery  charging,  and  by  pushing  the  TEST  button  to  check  the 
emergency  circuit.  The  led  strip  should  light  as  long  as  the  TEST 
button  is  pressed.

4.

It is suggested to check every 6 months the minimum autononous 

duration  by  disconnecting  the  mains  power  supply

Count  the 

time  that    the  led  strip  lights  and  in  case  of  less  time  than  the 
nominal autonomy, the battery must be replaced. If the measured 
time is considerably less than the nominal autonomy

 

  In  case  of  battery  or  led  strip  replacement,  these  must 

be replaced by parts of the same type,

 by the manufacturer or 

by 

a competent person.

t  i

in battery 

recycling points.

 

Do not incinerate.

The  light  source  contained  in  this  luminaire  shall  only  be 
replaced by the manufacturer, his agent or a similar qualified 
person.

NOTE! The light source is non-user replaceable.

  If  the  luminaire  doesn’t  work  as  described 

above contact the installer.

 

contact the 

installer.

5.

In  case  of  inactive  use  for  a  period  greater  than  2  months, 

disconnect the battery by pulling out the battery’s connector.

 

6

.

I

s  not  allowed  to  discard  batteries  into 

common trash bins, they must be discarded only 

923378005_

09_009

1
1
1

Luminaire
Mounting accessories
Manual

Package Contents

General

1

Reviews: