background image

Page

 

1

 

from

 

5

923037016

_09_00

1

SELF-TESTING NON MAINTAINED EMERGENCY LUMINAIRE WITH WIRELESS COMMUNICATION

TECHNICAL CHARACTERISTICS

 (

for LED MODULE Specifications see page 5)

220-240V AC/50-60Hz

90 min.

<24 h

POWER-CHARGE indicator, LAMP FAULT–BATT. FAULT indicator, TEST button

From overcharge and deep discharge

IP42

2x12V/7Ah

  White Power LEDs

13

.

3W/

14

VA

o

5 to 40  C

Up to 95% 

Aluminum, ABS/PC, PC

3 years 

(1 

year for the battery

)

  3200lm 

302 x 94 x 350 mm.

6310gr.

Thank you for your trust in our products  

Olympia Electronics -  European manufacturer

GRL-37/180/WL

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

EXTERNAL DIMENSIONS 

CONSTRUCTION MATERIALS 

TYPICAL WEIGHT

GUARANTEE 

OPERATION VOLTAGE

MAXIMUM POWER CONSUMPTION
BATTERIES (Pb)

CHARGING TIME

INDICATIONS - CONTROLS

BATTERY PROTECTION

MINIMUM AUTONOMOUS DURATION

DEGREES OF COVER PROTECTION

PRODUCED IN ACCORDANCE WITH

EMERGENCY ILLUMINATION

LIGHT SOURCE

12V/7Ah

180 min.

4120gr.

GRL-37/90/WL

o

These  luminaires  are  used 

(

ta  40 C

)

  where 

emergency light is needed.

 

Each luminaire must 

be  connected  permanently  to  the  mains  power 
supply.

 

OPERATION DESCRIPTION 

GENERAL

When  the  unit  is  connected  to  the  mains  power 
supply (after connecting the battery) the indicator 
LAMP  FAULT  –  BATT.  FAULT  remains  OFF 
whereas the indicator POWER CHARGE blinks to 
indicate that the batteries are charging. When the 
batteries are fully charged this indicator will light 
permanently.  If  this  indicator  does  not  light  then 
probably  the  battery  has  not  been  connected.  If 
the batteries are connected and the indicator does 
not light then contact a qualified service technician 
for  assistance.  The  charging  procedure  is 
monitored by a microprocessor and is based on a 
3 stage cycle thus ensuring a fast and full charge 
of the battery. The charge current is supplied by a 
high efficiency switch mode power supply which 
ensures  perfect  charging  even  during  the 
fluctuations of the mains power supply.

BATTERY CUTOFF

The unit enters this state during the power supply 
failure  and  when  the  battery  has  been  fully 
discharged.  In  this  state  the  luminaire  draws  the 
least power from the battery in order to prevent 
deep discharge.

Is accomplished by briefly (<1 sec.) pressing the 
TEST button. This permits  the user to test the good 
operation of the luminaire’s emergency circuit.

 

The 

unit simulates a power failure and the lamps are lit 
using the batteries. This manual test does not affect 
the automatic test

.

When  the 

luminaire  is  in  emergency  mode

,  with 

corresponding  press

ing

s  of  the  button,  we  ca

n

 

choose 

the  illumination  of  100%,  50%,  33% 

  or 

turned off

, either to increase the autonomy time or 

not  to consume 

the 

battery  power  unnecessarily. 

This  option  is  canceled  when  the  network  is 
restored.

MANUAL TESTING

DIMMING OPTION

TX POWER

TX/RX FREQUENCY RANGE

11dBm

868.150-868.450MHz

EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2,

EN 61000-3-3,

 

EN 62311, ETSI EN 303 446-1 V1.1.0, ETSI EN 300 220-2 V3.1.1