MAINTAINED EMERGENCY ILLUMINATION SIGNS (for ships)
Thank you for purchasing this product of Olympia
Electronics. A European manufacturer.
GENERAL
These sign illumination luminaires use a new
technology, friendly to the environment , with high
illuminated L.E.D.s. L.E.D. technology has very
low power consumption.
These luminaires are used on ships (indoors)
(
ta
o
40 C
)
where emergency light is needed.
In this type of marking panels, the PVC overlay is
mounted on the marking panel with 4 plastic screws,
and it can be changed by change the PVC overlay in
accordance with the desired result.
Each model combines modern, aesthetics, together
with functionality. The exit illumination signs are
used in every public area where clear direction and
good appearance are important.
All models must be permanently connected to the
mains power supply as shown on page 2.
The legend is screened on to a clear acrylic sheet
which has the marking on the marking panel with the
light that comes from the top of the luminaire and
diffracts, giving light to the marking panel.
The luminaire has an indication (CHARGE) for the
charging of the battery and a (TEST) button to TEST
the emergency circuit and the LEDs for good
operation only when the luminaire is powered by the
mains power supply. The unit must be mounted in a
clearly visible area and can either be hung on a
ceiling or mounted on a wall depending on the
requirements of the installation. The package
includes all the required materials for mounting on
the wall or on the ceiling. The pages 2 and 3 show
us the mounting methods.
WARNING !!
1. Read carefully this instruction manual.
2. Before service interrupt the mains power supply.
3. The device must be connected to the mains power
supply thru a fuse dependent by the total amount of
the line’s power load
.
4. It is sugested to check every month the indication
LED for battery charging, and by pushing briefly the
TEST button to check the emergency cirquit. The sign
should light for a few seconds powered by the battery
and then, will turn to normal operation
. In the opposite
condition contact the installer.
5.
full
Every six months, a
duration check should be
carried out
.
by disconnecting the mains power supply
Count the autonomous duration of the luminaire and
in case of no correspondence to stated emergency
duration replace the battery The replacement of the
.
battery must be done using parts of the same type, by
the manufacturer or by a competent person.
6.
In case of inactive use for a period greater than 2
months, disconnect the battery by pulling out the
battery’s connector.
7
Replaced batteries must not be thrown into
.
trash bins. They must be returned to special
battery disposal points. Do not incinerate.
NOTE: LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
1: Maintained (*)
A: Including test device
180: 3 hour duration
(*)
Maintained operation: The luminaire lights its
illumination source, when it is powered by the mains
power supply or not
.
Non-Maintained operation: The luminaire lights its
illumination source,
only in power supply’s failure.
922503465_09_001
Page
1 from
5
TECHNICAL CHARACTERISTICS
Operation temperature range
Relative humidity
External panel's dimensions
External dimensions (LxWxH)
Typical weight
Guarantee
Mains voltage
Maximum power consumption
Battery (Ni-Cd)
Recharging time
Battery protection
Minimum emergency duration
Degrees of cover protection
Class of cover protection
Produced in accordance with
Light source intensity (Mains / Emerg)
220-240V AC/50-60Hz
3h
24h
Overcharging and full discharging protection
IP 40
class
II
+
IEC 60092-306
3.6V/1Ah
105lm/85lm
85lm/85lm
3W / 8VA
3W /
7.5
VA
ο
0-40 C
up to 95%
280x100mm
305x25x155mm
3 years (1 year for the battery)
340x170mm
365x25x225mm
High Quality European based Manufacturers
520gr.
850gr.
MLD-34D/w/MAR
MLD-28D/w/MAR
EN 60598-1, EN 60598-2-22
, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
, EN 1838 + IEC 60092-306