background image

Quick Reference

   

CM 1830 Cash Register

5/621/3300 (13)

Olympia    09.2001

Page 2

All rights reserved.

Clearing faults

Incorrect entries or fault status (acoustic signal) can be cleared by pressing the 

6

 key.

Department registration

Enter the price without a decimal point (max. 9 digits).

Price

Department

PPPPPPPPP

x

Or: If items (PLUs) should be registered several times:

Number of PLUs

Price

Department

NNNN

i

PPPPPPPPP

x

The sum of NNNN x PPPPPPPP is limited to the maximum capacity of the cash register.

PLU registration

Scan the PLU, enter the PLU number or EAN code.

PLU number

PLU

E.g. 

7./

b

Or: If items (PLUs) should be registered several times:

Number of PLUs

PLU number

PLU

NNNN

i

e.g. 

7./

b

The sum of NNNN x PLU price is limited to the maximum capacity of the cash register.

Conclude receipt

After all the PLUs have been registered, press the 

y

 key to display the subtotal. Enter the amount tendered

without a decimal point and conclude the receipt by pressing 

O

, for example.

Amount tendered

Conclude receipt

y

PPPPPPPPP

e.g. 

O

Error correct and void

Incorrect registrations can be corrected directly after the entry itself or after the transaction.
Error correct (direct void): The last item entered during a registration can be cancelled directly.

l

Entry is cancelled.

Void: Errors in amounts, PLU prices and department prices for transactions entered previously can be corrected.

k

Activate the void function.

Enter the registration to be voided.

Void refund/returned goods: Revision of transactions is possible by entering the respective amounts, PLU numbers,
department prices or scanning the item.

U

Activate the Refund function.

Enter the registration to be revised.

E.g. 

O

Miscellaneous functions

s

Cash register is opened.

o

Enter the amount for payments out in cash and press this key.

n

Enter the amount to be received on account, press this key and conclude the receipt by pressing

O

 or 

w

 or e.g. 

.[[

.

E

Enables the selection of departments 11 to 20 if this function has been activated.

I

Following a registration or subtotal, press this key before entering a percentage premium.
Example: Entry for 10%:  

.7I

.

J

Following a registration or subtotal, press this key before entering a percentage discount.
Example: Entry for 5%:  

2J

.

8

Interrupts the registrations for Customer A and saves the sales registered. Customer B can then be
served. On completing Customer B, the system returns to Customer A to continue the transaction.

Summary of Contents for CM1830

Page 1: ...lid or onto the paper reel Close the printer lid Press the 6key Paper reel The paper reel is required when the journal paper should be rolled onto it 1 Open the printer lid 2 Remove the paper reel 3 Thread the end of the journal roll in the slit of the paper reel 4 Insert the paper reel in the reel guides provided for it 5 In order to remove the journal paper after it has been rolled up on the ree...

Page 2: ...the entry itself or after the transaction Error correct direct void The last item entered during a registration can be cancelled directly l Entry is cancelled Void Errors in amounts PLU prices and department prices for transactions entered previously can be corrected k Activate the void function Enter the registration to be voided Void refund returned goods Revision of transactions is possible by ...

Page 3: ...ted out nw Program flags E g Flag 07 Time 4n e g 707 y O Activate Flag 7 Time in the basic program Enter the time Store the setting and move on to the next flag Conclude programming and exit programming mode FLAG 01 VAT DECPT Tax rate Date format Decimal places 3 2 Recommended setting 0 Net price excluding tax Date MM DD YYYY 1 Net price excluding tax Date DD MM YYYY 2 Gross price including tax Da...

Page 4: ...e for 10 5 surcharge always enter a 4 digit number without decimal point FLAG 18 DISCOUNT Fixed discount percentage 0 2 5 0 Example for 2 5 discount always enter a 4 digit number without decimal point FLAG 19 PRNRNDFLAG Duplicate receipt Printer on off Rounding 1 0 0 Recommended setting Duplicate receipt 0 Dup rcpt no Print Training yes CCL no 1 Dup rcpt yes Print Training yes CCL no 2 Dup rcpt no...

Page 5: ...y calculation 0 No currency rate printout 1 Currency rate is printed FLAG 37 PASSWORDT Password for Training mode 0 0 0 0 No password Password 0001 to 9999 FLAG 38 KEY CONTROL Receipt on off Clerk code on off 0 0 Recommended setting 0 Clerk key is activated 1 Clerk key is deactivated 0 Receipt on off key is activated 1 Receipt on off key is deactivated FLAG 39 PERCENT KEY CTL Discount Premium 1 0 ...

Page 6: ...Close the tax rate program Note The tax rate entered must have 6 or 5 digits E g 7 input 47777 Programming departments x e g 66 y e g 7 673 y y O Activate the department program Enter the fixed price Store the fixed price Enter the assignment 0 price is added 1 tax rate 1 19 group 19 0 itemized receipt 6 number of digits for a price Store the assignment and move to the next setting Enter the name ...

Page 7: ... or by using a scanner We recommend using a scanner Store the EAN code Close the PLU program Press code Publications from the press are programmed in the same way as PLUs Programming is performed via the 13 character EAN13 code The structure of the press code differs in Germany France and Spain D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 4 3 9 9 1 1 7 7 0 5 5 0 9 Language code Media number Price in...

Page 8: ...1 compulsory input 5 decimal places of the six digit conversion factor y Move to the next setting 0 Enter the name y 62250 Define the conversion factor for cash payments in Euro and Euro table three way currency conversion FCE 3 y Move to the next setting 2 1 compulsory input 5 decimal places of the six digit conversion factor y Move to the next setting 1 Enter the name y 170066 Define the convers...

Page 9: ...ld print x y 1 2 3 z Space 0 00 A B C D E F Refund 7 8 9 4 5 6 1 2 3 0 00 Switch back to upper case letters by pressing U Error Message Printer In the case of a printer error the message º Æ Ä appears in the display Switch the cash register off immediately and disconnect the power plug Check that the paper rolls and ribbon are correctly inserted whether the paper or ribbon are damaged or objects h...

Page 10: ...as been withdrawn from sales E63 Discount is possible for this PLU registration E64 The PLU index is outside the range E65 The number of digits permitted for price entry for departments has been exceeded E70 It is not necessary to enter the clerk code E71 The clerk code entered exceeds four digits E72 The clerk code is incorrect E80 The input must be positive or zero E81 The item barcode was not f...