MODEL

FUEL

MIN/MAX(kg/

h)

CONTROL

VOLTAGE

(V)

MOTOR

(60㎐/kW)

GEAR 

PUMP

OIL  HOSE

MOTOR 
POWER

INHALATION

380V

RETURN

220V

LT-40U

20~40

HI-LOW-OFF

AC3φ220/38

0

O.45

AS47A

PT  1/4"
PT  1/4"

1.2
2.1

LT-40UH

20~40

LT-45U

20~45

0.75

PT  3/8"
PT  1/4"

1.7
3.0

LT-45UH

20~45

LT-60U

25~54

1.1

AN-77

2.4
4.1

LT-60UH

25~54

LT-80U

34~68

LT-80T

34~68

HI-LOW-OFF

or 

MODURATING

LT-100

30~98

HI-LOW-OFF

1.5

AJ-6

PT  3/8"
PT  3/8"

3.3
5.7

LT-120

51~123

HI-LOW-OFF

or 

MODURATING

2.2

LT-150T

60~150

HI-MID-LOW-O

FF

or 

MODURATING

3.0

4.7
8.2

LT-200T

65~200

HI-MID-LOW-O

FF

or 

MODURATING

4.0

7.5

13.0

LT-250T

71~214

HI-MID-LOW-O

FF

or 

MODURATING

5.5

E-7

11.8
20.4

LT-300T

80~250

7.5

TA-2

PT  1/2"
PT  1/2"

15.8
27.3

LT-400T

108~330

11

20.4
35.5

LT-500T

136~408

11

20.4
35.5

LT-600T

194~583

15

20.4
35.5

LT-700T

167~668

18.5

20.4
35.5

1.  INTRODUCTION  OF  PRODUCT.

LT-Series  oil  Burner  is  also  designed  and  manufactured  upon  our  well  experienced  technique 

and  is  made  of  motor,  oil  pump,  fan,  ignition  equipment  and  automation  in  single  body.

the  highly  pressurized  fuel  particulates  are  perfected  burnt,  which  minimizes  smoke  it  has 

following  benefits.

■  it  is  easy  to  check  and  maintain  as  a  hinge  type.

■  All  the  automatic  devices  are  assembled  in  an  integrated  method.

■  it  can  operate  both  automatically.  emergency  operation  is  possible  when  the                     

automatic  device  is  out  of  order.

1)  BURNER  SPECIFICATION.

Summary of Contents for LT-100

Page 1: ...OLYMPIA BURNER OPERATING MANUAL MODEL LT 40 45 60 80 100 120 150 200 250 300 400 500 600 700 OLYMPIA INDUSTRIAL CO LTD ...

Page 2: ...ATION SYSTEM 4 HOW TO INSTALL FUEL PIPE SYSTEM 5 TIME CHART 6 ELECTRIC CIRCUIT DIAGRAM 3 HOW TO USE MAJOR PARTS 1 COMBUSTION HEAD DIMENSION 2 HOW TO ADJUST COMBUSTION OF AIR FLOW RATE 3 HOW TO DISASSEMBLE CLEAN AND REPLACE NOZZLE 4 FLAME DETECTOR 5 GEAR PUMP 6 IGNITION TRANSFORMER 7 FUEL FILTER 4 GENERAL BURNER OPERATION 5 HOW TO CHECK BURNER CAUSE OF TROUBLE AND COUNTER MEASURE 1 CHECK OF BURNER ...

Page 3: ... 214 HI MID LOW O FF or MODURATING 5 5 E 7 11 8 20 4 LT 300T 80 250 7 5 TA 2 PT 1 2 PT 1 2 15 8 27 3 LT 400T 108 330 11 20 4 35 5 LT 500T 136 408 11 20 4 35 5 LT 600T 194 583 15 20 4 35 5 LT 700T 167 668 18 5 20 4 35 5 1 INTRODUCTION OF PRODUCT LT Series oil Burner is also designed and manufactured upon our well experienced technique and is made of motor oil pump fan ignition equipment and automat...

Page 4: ...2 COMBUSTION PERFORMANCE GRAPH ...

Page 5: ...3 SIZE AND DIMENSION LT 40 45 60 DIMENSION ...

Page 6: ...olled as follows depending on the number of nozzle two nozzle 2 position control hi low off three nozzle 3 position control hi mid low off one proportional nozzle proportional control modulating how to control air flow rate two nozzle damper motor or hydraulic cylinder type three nozzle damper motor type one proportional nozzle modulating motor type ...

Page 7: ...4 EXPLODED DRAWING OF BURNER AND PART NAME 1 LT 40U 45U 60U BURNER EXPLODED DRAWING ...

Page 8: ... 2 LT 40UH 45UH 60UH BURNER EXPLODED DRAWING ...

Page 9: ... 3 LT 80U 100U 150 200 250 300 400 500 600 700 BURNER EXPLODED DRAWING LT 80T 100T 150 200 250 300 DAMPER MOTOR LT 250 300 400 500 600 700 3NOZZLE ...

Page 10: ... 400 D 228 228 315 350 430 430 E M10 M10 M14 M14 M16 M16 2 HOW TO CONTROL BURNER 1 BURNER COMBUSTION FURNACE DIMENSION 2 HOW TO INSTALL BURNER 1 burner assembly sequence refer to above sketch insert gasket into the burner hinge insert burner to the boiler fire outlet or combustion furnace and tightly fasten after adjusting the burner in the hinge fix the burner with hinge pin ...

Page 11: ...mbustion gas leaks after installing the hinge type burner use care so that no part of ignition bar is damaged or deformed during assembly of frame secure enough working space to check and maintain burner flange tube type burner LT 40U LT700T hinge tube type burner LT 40UH LT 60UH 3 DIAGRAM OF FUEL CIRCULATION SYSTEM ...

Page 12: ...s plug when oil tank is below burner H its height must be less then 2 4m the inlet hole should place at 20cm higher then the floor of oil tank in order not to flow in foreign subtainces it is recommended that oil pipe be welded in order not to flow in air in case of fixing several pipes inlet and return pipe must use an enough space pipe in inside diameter return pipe had better not use valve if o...

Page 13: ...5 TIME CHART ...

Page 14: ... 6 ELECTRIC CIRCUIT DIAGRAM ...

Page 15: ... MODURATING TYPE ...

Page 16: ... 1 COMBUSTION HEAD DIMENSION in case of adjusting C size be careful not to touch the and of ignition bar with diffuser or diffuser is not stained with oil 2 HOW TO ADJUST COMBUSTION AIR FLOW RATE 1 hydraulic cylinder structure ...

Page 17: ...bustion then fully tighten the nut A ⓑ second stage high combustion air adjustment loosen the nut D in the high combustion mode and tighten adjuster nut C to increase air flow rate until no smoke coming out from the chimney when adjustment is over fully tighten the nut D so that the adjuster nut is not loosened 2 damper motor structure ...

Page 18: ...diagram how to adjustment damper damper gauge consists of from 0 to 10 0 indicates complete close and 10 indicates complete open disconnect power adjust each CAM by deciding the position depending on the combustion rate ...

Page 19: ... low combustion damper CAM when the s w is out of order replace the s w when it is completely closed use the manual adjuster knob to set in ti the low combustion opening position ⓑ when pressing the high overrun protection s w readjust the high combustion damper CAM when the s w is out of order replace the s w 3 HOW TO DISASSEMBLE CLEAN AND REPLACE NOZZLE the nozzle sprays fuel through fine hole a...

Page 20: ...lacement b how to disassemble and check nozzle separate filter clean the filter using kerosene separate the gelical support using a screwdriver clean the groove using kerosene and thin wire do not use iron wire or needle otherwise the nozzle hole may widen after the nozzle hole is clean assemble nozzle in the reverse order make it fasten it set up ...

Page 21: ...econds after burner ignitions check whether there is a soot or dust on the flame sensor of the flame detector thoroughly remove soot or dust from the flame sensor if any if soot or dust is accumulated on the flame sensor of the flame detector burner stops operation therefore it is required to clean the flame sensor using clean dry cloth every month 5 GEAR PUMP 1 external drawing and specification ...

Page 22: ...reasing 3 how to purge air from the pump turn the gear pump air purge bolt counterclockwise 3 to 4 times with spanner operate burner then air bubble comes through the air exhaust hole of the gear pump then clean oil discharges then stop burner operation and fully tighten the air purge bolt then operate burner if air is not completely removed within 16 seconds burner stops operation when pressing r...

Page 23: ...r emergency operation only continue to check conditions of flame during manual operation high combustion valve on automatic operation by inter lock auction take care of the ignition transformer as high voltage is applied to the ignition transformer 7 FUEL FILTER how to handle fuel filter the fuel filter removes foreign substance from fuel when burner does not generate flame as no fuel is fed even ...

Page 24: ...voltage and fuel meet the burner specification discharge air from the fuel pipe system check whether or not the burner nozzle corresponds the boiler or furnace capacity maintenance of burner clean the ignition bar if it is contaminated clean nozzle and nozzle adapter if soot is accumulated on the diffuser burner fails to ignite remove the soot from the diffuser check and clean oil filter if requir...

Page 25: ...2 BURNER TROUBLE ACTION TABLE ...

Page 26: ...r raise discharge pressure discharge air check valve and clean filter replace and repair adjust damper replace and repair replace and repair replace and repair when combustion stop immediately after ignites 1 flame sensor is contaminated 2 flame sensor is out of order 3 protector relay is out of order clean replace and repair replace and repair combustion is unstable or smoke occurs 1 hydraulic pr...

Reviews: