Monitoring
G
22
Overview of Monitoring Functions
Monitoring
functions
Acoustic
alarm signal
Internal telephone
dialling unit active
Silent mode
No
Yes with screening function
Alarm mode
Yes
Yes
At Home mode
Yes
No
Disarmed mode
No
No
Emergency call
(SOS)
No
Yes with handsfree function
Panic alarm
Yes
No
Switching the Monitoring Functions On/Off
NOTE: Before switching any functions on, inform all the other
people living in the residence regarding the location and
method of operation of the wireless alarm system.
NOTE: The alarm period of the acoustic alarm is restricted from
a minimum of 1 minute to a maximum of 10 minutes de
pending on the configuration.
The wireless alarm system distinguishes between 4 types of alarm:
1.
Alarm mode
When Alarm mode is active and an alarm is triggered, an acoustic alarm is issued
and the internal telephone dialling unit is activated.
2.
At Home mode
When At Home mode is active and an alarm is triggered, only an acoustic alarm
signal is issued.
3.
Silent mode
When Silent mode is active and an alarm is triggered, only the internal telephone
dialling unit is activated. A voice message requests the subscriber called to press
the
[1]
button on their phone/mobile. The screening function is activated.
4.
Disarmed mode
When Disarmed mode is set, the alarm system is deactivated.
The monitoring functions are confirmed by a voice message.
NOTE: When triggered, the smoke detector always issues an
acoustic alarm signal (immediately) regardless of the
wireless alarm system! The response of the base unit is
dependent on the type of alarm set and the setting of the
Flood & Smoke
menu option.
You can activate the required alarm type on the base unit or via the wireless remote control
supplied as follows:
NOTE: If an outdoor siren is registered on the base unit, the
alarm can only be stopped by the remote control unit
after 15 seconds at the earliest.