146
EPOCH 4PLUS
9.16
AWS
The AWS software option for the EPOCH 4PLUS assists with performing inspections
covered under the American Welding Society Structural Welding Code for steel. This
code provides inspectors with a method to classify discontinuities found in welds using
ultrasonic inspection. This code uses the following formula to develop an indication rating
for a reflector found during an inspection:
A – B – C = D, where:
A = Discontinuity Indication Level (dB)
B = Reference Indication Level (dB)
C = Attenuation Factor: 2*(soundpath in inches – 1 inch) (dB)
D = Indication Rating (dB)
As an AWS inspector, you must take the Indication Rating (D) that is calculated based on
A, B, and C to an Ultrasonic Acceptance – Rejection Criteria table produced by the AWS
in order to classify the severity of the discontinuity. When performing an inspection, you
are required to develop an AWS report that lists the values for all variables above as well
as transducer information, discontinuity length and location, and your overall evaluation
of the discontinuity.
For further details regarding the test equipment, methods, interpretation, and
classification requirements for these inspections, refer to the AWS Code Book.
9.16.1
AWS and the EPOCH 4PLUS
Olympus NDT
TM
developed the AWS D1.1 software option for the EPOCH 4PLUS to
simplify your tasks and lower the overall inspection time. This is accomplished by having
the EPOCH 4PLUS perform some required calculations automatically and also by
allowing you to document discontinuities in the EPOCH 4PLUS’s datalogger for
reporting purposes.
The EPOCH 4PLUS can also transfer inspection data to the GageView PRO Interface
Program to aid in report generation. This program allows you to view the instrument setup
parameters, the waveform generated by a discontinuity, the discontinuity’s soundpath and
location information, and all values for the AWS D1.1 formula variables.
9.16.2
Operating the AWS D1.1 Software
The first step in operating the EPOCH 4PLUS for AWS D1.1 inspections is to calibrate the
instrument for the transducer and test conditions.