background image

Filter sets

Eyepieces

100W mercury lamp housing

100W mercury apo lamp housing

Power unit

Reflected light fluorescence illuminator

SZX16 zoom body

Rotatable

analyzer

1/4 wavelength
retardation plate*

1

Ring light guide

*

1

 Incorporated in SZX2-ILLC16  *

2

 Cannot be attached to SZX2-FO

30˚ trinocular tube

Tilting trinocular tube

Light beam splitter

Photo adapter

Coaxial reflected light illuminator

Filter 
adapter

Spot lens

Light protective shield

Revolving nosepiece*

2

Dual inter-lock 
light guide

Dual combination
light guide

Light source

Dual flexible light guide

Mirror units

Coaxial reflected
light fluorescence
illuminator

Light beam 
splitter

Photo adapter Eyepoint 

adjuster

Drawing attachment

SZX10 
Zoom body

Eyepieces

30 degree 
trinocular 
tube

Tilting trinocular
tube

Binocular 
tube

30 degree 
binocular 
tube

Tilting binocular tube

Power unit

Power unit

Light protective shield

100W mercury lamp housing

100W mercury apo lamp housing

Discussion tube

Coaxial illuminator

Side-by-side 
discussion tube

Dual flexible light guide

Large stand for SDO

Light source

Filter 
adapter

Spot lens

Revolving nosepiece

Dual inter-lock 
light guide

Ring light guide adapter for SZX

Analyzer

1/4 wavelength 
retardation plate*

1

Ring light guide

*

1

 Incorporated in SZX2-ILLC10

LG-R66PL
Analyzer and polarizer set 
for LG-R66

Analyser 

Polarizer

Dual combination 
light guide

Black/White

stage plate

Stage plate 
for fluorescence

Cup stage

Gliding stage

Focusing unit

Simple 
polarizer

Manipulator
adapter

Large stage plate

Circular 
rotatable stage

Circular 
rotatable stage

Square mechanical stage

BH stage adapter 
type 1

BX stage adapter 
type 1

Accessories

Focusing units

Illuminators

Foot Switch

Hand Switch

AC adapter

Control unit

Motorized focusing unit

Focusing unit

Fine focusing 
unit

Fine focusing for heavy loading

400mm pillar

600mm pillar

Slim LED transmitted 
light illumination base

AC adapter

Dumper for SZX2 illumination base

Transmitted light 
illumination base

High-level transmitted 
light illumination base

Transmitted light guide adapter unit

6V30W lamp socket

Drop prevention collar

Light guide

BF/DF transmitted 
light illumination base

Standard 
stand

BX stage 
adapter type2

Large stand

Universal stand type 2

Mechanical stage

MATS-55SZX2A/
MATS-55SZX2B

Thermo plate

MI-IBCSZXF

CO

2

 incubator

Summary of Contents for SZX16

Page 1: ...RESEARCH STEREOMICROSCOPE SYSTEM...

Page 2: ...chieved by the highest available NA and a depth of field perceived as deeper from multi wave length astigmatism free design that absolutely minimizes astigmatism SZX2 is ergonomically redesigned espec...

Page 3: ...e illumination base design P09 P10 Comfortable operability Tilting trinocular tube with an optimum convergence angle and new slim illumination base effectively eliminates fatigue resulting from long t...

Page 4: ...rity Olympus new SDF objective lenses provide the highest NA with 900lp mm resolution Optimum specimen viewing from large field overview to microstructure along with instant zoom function to select ob...

Page 5: ...ntional model SDF Objective Lens Series Highest available NA The SZX16 realizes the highest NA 0 3 among stereomicroscopes with 2x objectives Optical performance is 30 better than that of comparable p...

Page 6: ...5 A new dimension in image clarity Unprecedented depth and sharp images dramatically enhance efficiency for a variety of tasks including specimen manipulation...

Page 7: ...objectives eliminates chromatic aberration throughout the zoom range and ensure excellent image quality without chromatic blur SZX16 new optics for equally easy handling of thick specimens Obtaining...

Page 8: ...7 A new dimension in image clarity From low to high magnification exceptionally bright and even fluorescence is assured for efficient screening...

Page 9: ...t the light of fluorescence to enhance and capture brighter fluorescence images in precise detail Even and seamless fluorescence observation from low to high magnification In correspondence with zoom...

Page 10: ...9 Effective combination of long WD and high NA Development of an ergonomic design Design focus on creating a wide working space and comfort Comfortable operability...

Page 11: ...ble for long time manipulation of live specimens Power consumption is about half that of a conventional 30W Halogen light source A life cycle of over 10 000 hours significantly reduces operation costs...

Page 12: ...11 Ergonomic design for working ease Users can work at ease regardless of height Ergonomic design reduces fatigue for maximum comfort...

Page 13: ...s increased Close positioning of zoom handle and focus handle enable stress free blind operation Fine adjustment of the focusing handle offers increased sensitivity for easy focusing at high magnifica...

Page 14: ...13 Digital imaging From brightfield to fluorescence observation several different specimens can be viewed at a high resolution recognized as leading the digital imaging world...

Page 15: ...g displayed at the high rate of 15fps for smooth easy to view display of live specimen images Digital zooming function wastes no time in focusing on selected areas The RGB 24 bit 16 7 million colors c...

Page 16: ...asy sterilization and other antiseptic procedures This stand provides a large working space to accommodate large specimens CO2 incubator MI IBCSZXF This CO2 incubator is developed especially for the S...

Page 17: ...With its 66mm diameter mount this ring light illuminator has been specially developed for stereomicroscope compatibility When mounted with ring light adapter SZX LGR66 LGR66 it provides bright unifor...

Page 18: ...1 10 is suitable for operations like specimen selection or dissection SZX10 provides wide viewing and assures fewer oversights while relieving fatigue Choose from a wide range of accessories to suit...

Page 19: ...ar tubes allow for variable eye points Users will find observation can be done in a natural posture thanks to the tilting head with an incline angle varying between 5 and 45 This fluorescence unit all...

Page 20: ...1mm Load capacity 0 10 0kg SZX2 FOF Fine focusing unit focus rack and pinion with roller guide with torque adjustment ring for coarse focusing coarse and fine coaxial handle built in counter balance c...

Page 21: ...8 28 6 1 7 22 9 1 4 14 3 0 9 11 4 0 7 4 2x 69x 7x 115x 11 2x 184x 14x 230x 22 4x 368x 28x 460x 59 5 3 6 35 7 2 2 22 3 1 4 17 9 1 1 11 2 0 7 8 9 0 5 6 3x 103 5x 10 5x 172 5x 16 8x 276x 21x 345x 33 6x 5...

Page 22: ...protective shield Revolving nosepiece 2 Dual inter lock light guide Dual combination light guide Light source Dual flexible light guide Black White stage plate Stage plate for fluorescence Cup stage...

Page 23: ...lens Revolving nosepiece Dual inter lock light guide Ring light guide adapter for SZX Analyzer 1 4 wavelength retardation plate 1 Ring light guide 1 Incorporated in SZX2 ILLC10 LG R66PL Analyzer and...

Page 24: ...5 7 8 lower right RIKEN Center for Developmental Biology Laboratory for Cell Asymmetry Dr Ayano Kawaguchi page 3 lower right Graduate School of Medicine and Faculty of Medicine the University of Tokyo...

Reviews: