7.3. firmware upgrade
Download the firmware upgrade software and latest firmware file for the from the official
OM Power website http://www.om-power.com/downloads. Store it to folder created on
your PC.
NOTE:
Use a serial null modem cable and connect to the PC port on the rear panel with a
COM port on the PC.
Open folder on your PC, find the
MX460L.exe file and run it.
Select SETTINGS and choose the COM port
you want to use. Baud rate should be 115200.
Close the window.
Select the Firmware tab and click on the LOAD
BIN button.
Choose Vxxx.bin file in the folder.
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.
Type of supported TCVR and
working
frequency are visible on the display.
AUTO LED is ON.
Type of supported TCVR and
working
frequency are visible on the display.
AUTO LED is ON.