background image

 

www.microscope.com 

 

Oversized 155 mm x 150 mm integral mechanical stage with low position coaxial 
controls. Range of movement 80 x 50 mm.  

 

Interpupillary adjustment range: 55 

– 75 mm  

 

Graduated, oversized knobs on coaxial coarse and fine (0.002mm) adjustments  

 

Limited Lifetime Warranty

  

 

Packed in a specially molded Styrofoam shipping container  

 

 

ASSEMBLY 

*Use figure 1 (page 5) to aid in assembly

 

1.  Remove  the  main  body  of  the  microscope  from  the  foam  box  and  place  it  on  a 

working table. 

2.  Install the trinocular body on the base. Tighten the screw on the right of the base 

to affix the body. 

3.  Insert the 10x eyepieces into the eyetubes. 

4.  Attach the four included objectives to the nosepiece in sequence from low 

magnification to high magnification.  Make sure the objectives are secure. 

 

Summary of Contents for OM139

Page 1: ...www microscope com OM139 Biological Microscope Instruction Manual Please read instructions carefully before using microscope ...

Page 2: ...bustibles near the bulb To avoid electric shock or damage to the instrument unplug the microscope before replacing the bulb Use only the recommended halogen bulb Wear gloves or cover the bulb with a protective sleeve Do not touch the glass with bare skin Turn off and unplug the microscope before moving Keep microscope on a level and sturdy surface The microscope should be kept at temperatures betw...

Page 3: ...pharmaceutical research physician offices college university and medical labs and veterinary clinics The OM139 has been manufactured under the strict guidelines established under ISO 9001 2000 Standards Certification number 3600 992054 Large extremely stable Euro style 25 cm x 21 5 cm base One set of 30mm DIN eyepieces Super Widefield 10x Inclined 45º trinocular head that is 360º rotatable Trinocu...

Page 4: ...n a specially molded Styrofoam shipping container ASSEMBLY Use figure 1 page 5 to aid in assembly 1 Remove the main body of the microscope from the foam box and place it on a working table 2 Install the trinocular body on the base Tighten the screw on the right of the base to affix the body 3 Insert the 10x eyepieces into the eyetubes 4 Attach the four included objectives to the nosepiece in seque...

Page 5: ...www microscope com Figure 1 1 2 3 4 5 5 6 7 8 9 11 10 12 13 14 15 16 17 18 12 20 19 21 22 23 24 25 26 27 28 ...

Page 6: ...ce PREPARATION BEFORE USE Refer to Figure 1 on previous page Insert the trinocular viewing head 2 into the microscope arm 10 and lock up bolt 19 per drawing Attach the objectives 11 to the screw hole of nose piece 3 per big and small gradation Place eyepiece 1 into the eye tube 2 Plug the power cord into the microscope base 22 Note Voltage of power supply must accord with the instrument The lamp w...

Page 7: ... specimen image 5 Adjust the interpupillary distance the distance between the eyes by sliding the eyepiece tubes left or right 6 When using the 100x raise the condenser 27 to the highest position and then drop a a slight bit of immersion oil on the surfaces of the objective itself and the slide and condenser Then view the specimen MAINTENANCE 1 When not in use a Always cover the microscope with th...

Page 8: ...iece Widefield10x 3 Mechanical stage 155mm x 150mm moving range 80mm x 50mm 4 Condenser Abbe N A 1 25 condenser 5 Focusing range 30mm division of fine focus adjustment 0 002mm 6 Interpupillary distance 55 75mm 7 Illumination Halogen lamp 6v 30w Power 220V 50Hz or 110V 60Hz NOTES ...

Reviews: