D877 MGB Rev01 HE250.docx
33/50
424 Pause ERS U
STEPPER upward start time delay from
ERS
dec
0
30
1
425 Pos Min MPP
STEPPER position inferior limit
step
0
23000
2000
<= P402
426 Pause ERS D
STEPPER downward start time delay from
ERS
dec
0
30
1
427 TemperZeroM
Flow meter zero temperature
°C
0
80
0
430 Start Time1
STEPPER starting time 1
s/1000
0
20000
150
432 StopPos MPP
STEPPER stopping position
step
0
23000
10
<= P402
433 StartPos2 D
Downward starting target position 2
step
0
23000
7000
<= P402
434 StartPos1 D
Downward starting ENR activation posit. 1
step
0
23000
1800
<= P402
435 StartTime2D
Downward starting opening time 2
s/1000
0
20000
4000
436 Pos Max MIS
Flow meter max position
0
10000
2400
437 Oil Vis 40
Oil viscosity at 40 °C
cSt
0,00
999,99
46,00 > P438
438 Oil Vis 100
Oil viscosity at 100 °C
cSt
0,00
999,99
8,40
< P437
441 Min Speed U
Upward minimum speed
m/s
0,000
0,100
0,010
442 Min Speed D
Downward minimum speed
m/s
0,000
0,100
0,005
443 Minim.Temp.
Minimum temperature limit
°C
0
80
5
444 StartTime3U
Upward starting time 3
s/1000
0
20000
4000
445 P0WaitTime
Waiting time at pressure 0
s/1000
0
20000
10000
446 StartTimeP0
Time searching flow at pressure 0
s/1000
0
20000
3000
451 ControlType
Control type: 1=PID, PID+Map, 0=Map
0
2
1
452 SP Calcul.
Deceleration
space
recalculation,
1=Activate
0
1
0
453 SignalSpeeD
Downward high speed signal: 1=Activate
0
1
0
454 OnOff V2+V1
Maintenance with high speed signal:
1=Activate
0
1
0
456 SP recovery
Levelling space recovery: 1=Activate
0
1
0
457 OnOff P1-P2
During manoeuvre P1 relay updating :
0=OFF, 1=ON, +2 speed bloccok under
P107
0
3
0
458 MinSP Low U
Upward minimum levelling space
mm
0
1000
150
459 MinSP Low D
Downward minimum levelling space
mm
0
1000
150
460 OnOff CompT
Flow meter temperature compensation:
1=Activate
0
3
1
461 PNP1 Test
PNP1 signal check test: 0=normal, 1= fixed
ON, 2= fixed OFF
0
9
0
462 RotDisplay
Display direction 0=right,
0
1
0
463 ErrRelay ON
Error output relay test: 0= nomal, 1=
blocked ON
0
1
0
464 E1 E2 Block
E1 E2 error block in PNP1
0
1
0
475 CanNodeType
CAN node type: 0=no ; 1=master; 2=slave
0
2
0
476 CanNodeAddr
CAN node address
1
99999999
1
477 Slaves
Slave nodes total number
1
7
1
478 CAN Active
CAN node activation:
0
1
0
479 Offset CAN
Offset value for CAN addresses
0
99999999
0
480 ConBoardCAN
CAN address control board
0
99999999
0
488 Test Cond.
Test condition with solenoid valve always
supplied: 1=ON , 0=OFF
0
1
0
489 MinPressure
Minimum Pressure limit
0,1
20,0
2,0
491 Offset MsT1
Flow meter zero temperature 1
°C
0
80
20