5.1
Parameters
The parameters of the series P1, P2, P3, P5 and P6 have free access, while those of series P4, P7 and P8
need the setting of parameter P199 with the value = 8369111 (user password), which will reset when you
disconnect the device or you re-enter in P199 parameter.
The P5 and P6 parameters (error stack) are read-only.
The parameters change has on the SCH001 board effect only with the selector position RSW = 1
Parameter
Nr Desc. Hand term
Large Description
Unit
Setting Range
Default
Value
Note
P1 Base Par.
BASE PARAMETERS
Min
Max
101 Piston Dia
Piston working diameter
mm
5
999
80
102 Pump Flow
Pump nominal flow
lt/min
1
1000
100
103 Tackle X:1
Roping Ratio
1
4
2
104 Pist.
Pistons number
1
4
1
105 TMAX limit
Maximum temperature limit
°C
10
80
60
> P110
106 PMAX limit
High pressure limit
bar
1
200
45
> P107
107 PMIN limit
Low pressure limit
bar
0
200
10
< P106
108 PS overload
Load Weighing
bar
0,1
200,0
30,0
109 Pist.Stages
Pistons stages number
1,000
4,000
1,000
110 TMIN limit
Low temperature limit
°C
0
80
4
< P105
111 Cabin Load
Cabin nominal load
kg
0
200000
600
199 UsPassword
User password
0000000 9999999 0000000 8369111
Parameter
Nr Desc. Hand term
Large Description
Unit
Setting Range
Default
Value
Note
P2 Upwars Par.
UPWARD PARAMETERS
Min
Max
201 %AccStart U
Upward initial acceleration change rate
%
0
100
1
202 Acc Dist
U
Upward accelation distance
m
0,000
10,000
1,500
203 %Acc End
U
Upward final acceleration change rate
%
0
100
100
204 HighSpeedU1
Upward high speed
m/s
0,000
2,000
0,600
205 HighSpeedU2
Second upward high speed (maintenance) m/s
0,000
2,000
0,300 < P204
206 HighSpeedU3
Third upward high speed
m/s
0,000
2,000
0,200 < P204
207 %DecStart U
Upward initial deceleration change rate
%
0
100
50
208 Dec Dist U1
Upward deceleration distance
m
0,000
10,000
0,400
209 Dec Dist U2
Second upward deceleration distance
m
0,000
10,000
0,400
210 Dec Dist U3
Third upward deceleration distance
m
0,000
10,000
0,400
211 %Dec End U
Upward final deceleration change rate
%
0
100
50
212 Low Speed U
Upward low speed
m/s
0,000
0,300
0,050 < P204,P205
213 Stop Dist U
Upward stopping distance
m
0,000
10,000
0,010
214 Acc Dist UR
Upward releveling acceleration distance
m
0,000
10,000
0,010
215 RelevSpeedU
Upward releveling speed
m/s
0,000
0,300
0,050 < P204, P205
216 Stop DistUR
Upward releveling stopping distance
m
0,000
10,000
0,020
217 HighSpeedU4
Fourth upward high speed
m/s
0,000
2,000
0,119 < P204
218 Dec Dist U4
Fourth upward deceleration distance
m
0,000
10,000
1,000