OMAX JetMachining® Center Operator’s Guide
Introduction
2 - 4
400433D-EN
Control Panel Switches
The front panel includes a main power switch, a power switch for the charge pump, and an emergency
stop switch (E-Stop):
Figure 2-5: Pump Control Switches
Main Pump Power Switch
This switch applies AC power to the pump and the table. When switched OFF, the pump and table
immediately stop. When switched ON, power is enabled for the pump; the pump is enabled but starts
only when commanded by the OMAX JetMachining Center.
WARNING!
The pump On/Off switch will not remain in the On position unless power to the pump unit is
received from the AC main power disconnect. Whenever power at the main disconnect is On,
there is always live AC power on the DIN rail and at the terminals inside the pump electrical
enclosure even when the pump On/Off switch is Off.
Emergency Stop Switch
Pushing the emergency stop switch in immediately shuts down the pump and JetMachining Center. The
emergency stop switch is disengaged (reset) by manually pulling it back to its original position. The
pump and JetMachining Center cannot be restarted until the emergency stop switch is reset.
Note:
Pushing the emergency stop switch in (either the emergency stop switch on the pump, or the emergency
stop switch on the JetMachining Center) immediately shuts down both the pump and the JetMachining
Center. If the JetMachining Center is being powered from a 115 VAC source other than that of the OMAX
pump, the pump’s emergency stop switch will not stop the JetMachining Center.
Charge Pump On/Off Switch
The charge pump boosts incoming water pressure and circulates water through the cooling lines. Cooler
water increases the life of the high-pressure pump seals.
The charge pump power switch controls only the charge pump. The charge pump must be running for
the high-pressure pump to start. If an attempt is made to start the high-pressure pump without the charge
pump running, the high-pressure pump will not start and an error message appears on its front panel
display.
emergency STOP
switch
(push in to stop)
high-pressure
pump On/Off
switch
charge pump
On/Off switch
Summary of Contents for JetMachining Center 2626
Page 8: ...OMAX JetMachining Center Operator s Guide viii 400433D EN ...
Page 12: ...OMAX JetMachining Center Operator s Guide xii 400433D EN ...
Page 22: ...OMAX JetMachining Center Operator s Guide Safety First 1 10 400433D EN ...
Page 140: ...OMAX JetMachining Center Operator s Guide OMAX Glossary 6 16 400433D EN ...