OMAX JetMachining® Center Operator’s Guide
Operation
3 - 24
400433D-EN
Shutdown Checkoff Sheet
Use the following checkoff sheet to ensure that all equipment shutdown tasks are completed and in the
required sequence. For more detailed shutdown instructions, refer to Shutting Down the JetMachining
Center, page 3-20.
WARNING!
Safety First – Always wear safety glasses, ear protection, and hand protection when
operating your OMAX JetMachining Center.
1.
Nozzle POSITIONED between slats
, 1 to 2 inches (2.54 - 5.1 cm) above the water level.
2.
Nozzle high-pressure test STARTED.
Click “Test”, “High”, and “Water”.
3.
Pump RUN for 20 seconds
to clean and clear all abrasives, then test stopped.
4.
Water LOWERED
to lowest level.
5.
Nozzle POSITIONED
at desired location for shut down.
6.
Floppy diskettes REMOVED
from drive.
7.
Terrain Follower foot SECURED
in up position.
8.
OMAX “Make” CLOSED
.
9.
Windows “Shut Down” CLICKED
.
10.
PC Controller POWERED OFF
.
11.
PC shutdown VERIFIED
(no PC lights; black monitor screen).
12.
Bulk feed hopper DEPRESSURIZED
(if applicable).
13.
Charge pump POWERED OFF
.
14.
Water supply valve CLOSED
.
15.
PC Controller POWERED OFF
.
16.
High-pressure pump POWERED OFF
.
17.
Air supply valve CLOSED
(air is off last so Terrain Follower will not drop the Z-axis).
18.
Water level air tank DEPRESSURIZED.
19.
Main
breaker box
POWERED
OFF
.
Your OMAX equipment is now properly shutdown.
Summary of Contents for JetMachining Center 2626
Page 8: ...OMAX JetMachining Center Operator s Guide viii 400433D EN ...
Page 12: ...OMAX JetMachining Center Operator s Guide xii 400433D EN ...
Page 22: ...OMAX JetMachining Center Operator s Guide Safety First 1 10 400433D EN ...
Page 140: ...OMAX JetMachining Center Operator s Guide OMAX Glossary 6 16 400433D EN ...
Page 144: ...OMAX JetMachining Center Operator s Guide Index 4 400433D EN ...