Back the ADO pressure adjustment knob (Figure 4-75) out a couple of turns counter-clockwise
(viewed from end of knob) to ensure the valve is not completely closed when the pump starts.
Caution:
The safety valve may fire due to excessive pressure if the pump runs with the nozzle shut off
and the ADO valve completely closed.
Figure 4-75: The ADO Pressure Adjustment Knob
Note:
Excessive tightening of the ADO knob may jam the valve stem into its seat. If resistance is met while
closing the valve, stop tightening!
4.
Launch the OMAX
Make
software and position the nozzle to accommodate a high-pressure, water-
only test.
5.
In Make, select
File/Open (Change Path Setup)...
to open the
Choose tool path for machining
Window
, then
select the
Variable Dump Orifice Adjustment Routine.ord
file:
Figure 4-76: Select the ORD file, Variable Dump Orifice Adjustment Routine
pressure adjustment knob
CW =
valve
closed
CCW = valve open